Specifying an additional syslog server, Disabling logging of a message level – Brocade Communications Systems Brocade ICX 6650 User Manual
Page 257

Brocade ICX 6650 Administration Guide
239
53-1002600-01
Syslog service configuration
10
Specifying an additional Syslog server
To specify an additional Syslog server, enter the logging host
specify up to six Syslog servers.
Brocade(config)#logging host 10.0.0.99
Syntax: logging host
Disabling logging of a message level
To change the message level, disable logging of specific message levels. You must disable the
message levels on an individual basis.
For example, to disable logging of debugging and informational messages, enter the following
commands.
Brocade(config)#no logging buffered debugging
Brocade(config)#no logging buffered informational
Syntax: [no] logging buffered
The
•
alerts
•
critical
•
debugging
•
emergencies
•
errors
•
informational
•
notifications
•
warnings
The commands in the example above change the log level to notification messages or higher. The
software will not log informational or debugging messages. The changed message level also
applies to the Syslog servers.
Changing the number of entries the local buffer can hold
You also can use the logging buffered command to change the number of entries the local Syslog
buffer can store. For example.
Brocade(config)#logging buffered 100
Brocade(config)#write mem
Brocade(config)#exit
Brocade#reload
Syntax: logging buffered
The default number of messages is 50.