Brocade Communications Systems Brocade ICX 6650 User Manual
Page 286

268
Brocade ICX 6650 Administration Guide
53-1002600-01
sFlow
11
Syntax: show sflow
The show sflow command displays the following information.
TABLE 56
sFlow information
Parameter
Definition
sFlow version
The version of sFlow enabled on the device, which can be one of the
following:
•
2
•
5
sFlow services
The feature state, which can be one of the following:
•
disabled
•
enabled
sFlow agent IP address
The IP address that sFlow is using in the agent_address field of packets
sent to the collectors. Refer to
Collector
The collector information. The following information is displayed for each
collector:
•
IP address
•
UDP port
If more than one collector is configured, the line above the collectors
indicates how many have been configured.
Configured UDP source port
The UDP source port used to send data to the collector.
Polling interval
The port counter polling interval.
Configured default sampling rate
The configured global sampling rate. If you changed the global sampling
rate, the value you entered is shown here. The actual rate calculated by
the software based on the value you entered is listed on the next line,
”Actual default sampling rate”.
Actual default sampling rate
The actual default sampling rate.
Brocade#show sflow
Flow version: 5
sFlow services are enabled.
sFlow agent IPv6 address: 2001:DB8:2
2 collector destinations configured:
Collector IPv6 2001:DB8:1, UDP 6343
Collector IP 10.37.224.233, UDP 6343
Configured UDP source port: 2000
Polling interval is 20 seconds.
Configured default sampling rate: 1 per 100 packets.
Actual default sampling rate: 1 per 100 packets.
The maximum sFlow sample size: 1300.
exporting cpu-traffic is enabled.
exporting cpu-traffic sample rate: 10.
83715 UDP packets exported
8931 sFlow flow samples collected.
sFlow ports: ethe 1/1/11 ethe 1/1/32 ethe 1/2/1
Module Sampling Rates
---------------------
Port Sampling Rates
-------------------
Port=1/1/11, configured rate=25, actual rate=25
Port=1/1/32, configured rate=10, actual rate=10
Port=1/2/1, configured rate=10, actual rate=10