Figure 166: query format window (power), Table 15: projector query response (power), Table 15 – Kramer Electronics WP-501 User Manual
Page 86

The Driver Manager
79
The Query Format is set to encode the projector response, as defined in
Table 15: Projector Query Response (Power)
The projector response is: 20H 85H 01H xxH 10H DATA01 ... DATA16
The projector status of operation appears in DATA06:
DATA06:
00H
04H
05H
06H
Idling
Power On
Cooling
Idling (error
occurrence)
An actual response could be:
20H 85H 01H 00H 10H 00H 01H 00H 00H 00H
04H FFH FFH FFH FFH
4. In the Query Format tab, set the query format, see
Figure 166: Query Format Window (Power)
5. In the Query Command Details tab, fill in the look up table (the Expected Result Table in the
Query Command Details tab).
The lookup table lets you match a command string (from the projector protocol) to a projector
state
and assign a status that will appear in Site-CTRL and the Web pages.
shows, for example, that the command 0x04 matches the On state
and that means that the status is OK; the command 0x06 matches an Error state and the Error
status is assigned and will appear in Site-CTRL and the Web pages.
1
On and STBY states are built-in and you can add other states as required (for example, Cooling, Error and so on)