The Triggers

40

6.7.2 System Inactivity Example

In this example, the Timer trigger is used to perform a sequence of actions if no signals are fed into

the AV room system for a predefined time period (for example, 20 minutes, see

Figure 74

). A

switcher (for example – the Kramer VP-411DS) will send out a dedicated serial command once all

PC sources are disconnected. We will use this command to trigger a 20 minute timer. Each action

list will start with a command to stop this timer. In the System Inactivity timer we will shut down

the display device and perform other shut off tasks.

Figure 74: Timer Trigger Flowchart – Inactivity Example

To indicate inactivity, you have to add a “Stop” trigger prior to the sequence of actions and a

“Start” trigger upon completion of the actions sequence.
This setup includes two steps:
Step I:

Define the Timer Trigger (which will be used for all the triggers)

Step II:

Define the Button (and other) triggers

Step I: Define the Timer Trigger
1. Click the Add Timer button.

The Timer Trigger Name window appears. Type the Trigger name (for example, System

inactivity):

Figure 75: The Timer Trigger Name Window (Inactivity)

2. Click OK.

The Timer trigger (in red) appears in the available triggers list: