Tab Area Settings

25

Table 7: The Device Settings Tab Features

Feature

Function

Device General Settings Area Includes the device information (master and auxiliary device)
Device ETH Settings Area

Ethernet information (If required, you can change information) and DHCP

27F

1

Enabled

Device Secure Settings:

Secure Mode:

OFF – the product definitions and configuration can be changed without

requiring a password

ON – a password is required to change the configuration and view or

change the device definitions

User pass:

This password lets you view the device definitions in Web Access and Site-

CTRL without changing the definitions

Admin Pass

Lets you change the device definitions and configuration via Web Access

and K-Config

Unlock Keypad PIN

code:

Set the key sequence

28F

2

to press to unlock the keypad in case it is locked by

a trigger (activated by pressing a button, a schedule or via Web Access)

Date and Time

This area applies to devices with an Ethernet connection and time server settings options and lets

you set the device’s internal clock to use with the scheduler (see

U

Section 6.5

U

).

The date and time can be set either manually, via a local server or via the Ethernet (see

U

Section

5.2.1

U

)

Read date and time Click button to read the device’s current date and time

Set Date and Time

Check Set from PC on Write Configuration to have the date and time

updated whenever writing a configuration.

Click the Set Now button to set the time from a connected PC Clock or to

use a Custom Date (selected by the user)

DST

Daylight Saving Time or Summer Time correction. Set to ON if necessary

Timezone

Set the time zone relevant to UTC (Coordinated Universal Time).

The time zone can be set from -13 to +12 hours relative to UTC in 15

minute intervals (00, 15, 30 or 45 minute intervals).

For example, the time zone in Adelaide, Australia is UTC +9:30, therefore

9:30 needs to be entered in Timezone for that particular location.

If the value entered is out of range, the following message appears:

Sync Date and Time Check “No Sync” or “From Server Address”

Note that the Date and Time area appears only for devices that include an Ethernet connector

and support this function

5.2.1

56B

Setting the Date and Time

You can set the date and time on machines that have an Ethernet connector to use with the

scheduler. You can set the time from several sources such as from a PC connected to the device, an

NTP (local) server, or the Ethernet. You can also set the time and date manually.
To read the current date and time on the device, click the Read button:

The device time and date appears:




1

Dynamic Host Configuration Protocol: Allows the network administrator to distribute IP addresses from a central point and automatically send a new IP

address when an Ethernet point is plugged into a different network location

2

Since the button number does not appear on the actual keypad, the system integrator should inform the user regarding the key sequence