The Driver Manager

63

9.1.2 Creating an IR Command

To create IR commands for a selected device, connect the FC-29 or RC device (with IR learning

capability) directly

1

to your PC via the USB connector and use the remote control transmitter

2

When an RC-6x (in the auxiliary configuration) is connected, although it is directly connected, it

should remain in the auxiliary state because if it is defined as master, it will not function when

reconnected to the Master room controller.

to

learn its IR commands.

To keep the RC-6x in the auxiliary configuration:
1. Connect the RC-6x directly to the USB connector. The following window appears:

Figure 134: Setting the Device as an Auxiliary Device

2. Click NO to keep the device in the auxiliary configuration.
3. Complete the connection of the device via the USB port:

Figure 135: Connect to IR Capture Device Window

If you have a problem connecting to the USB port, make sure that you have installed the Kramer

USB driver (see

Section 2.2

1

Whether it is defined as an auxiliary device or a standalone Master

).

2

Of the machine from which you want to learn the IR commands. For example, use the DVD remote control transmitter to write the DVD commands to the

driver manager