Allied Telesis AT-S62 User Manual
Page 161

AT-S62 Command Line User’s Guide
161
parameter are:
disabled No
flow
control.
enabled
Flow control is activated.
auto
The switch sets flow control to match
flow control on the end node
connected to the port. If the end node
is using flow control, the switch port
also uses flow control. If the end node
is not using flow control, neither will
the switch port.
fctrllimit
Specifies the number of cells for flow control. A cell
represents 64 bytes. The range is 1 to 57,344 cells.
The default is 8192. The default value is 8192
packets.
backpressure
Controls backpressure on the port. Backpressure
applies only to ports operating in half-duplex mode.
Possible values are:
yes, on, true, enabled
Activates backpressure on
the port. These values are
equivalent.
no, off, false, disabled
Deactivates backpressure
on the port. This is the
default. These values are
equivalent.
bplimit
Specifies the number of cells for backpressure. A cell
represents 64 bytes. The range is 1 to 57,344 cells.
The default is 8192.
bcastfiltering
Controls the broadcast filter. These parameters are
equivalent. Possible values are:
yes, on, true, enabled
The port forwards
broadcast frames. These
values are equivalent.
no, off, false, disabled
The port discards all
ingress broadcast frames.
These values are
equivalent.
holbplimit
Specifies the threshold at which the switch signals a
head of line blocking event on a port. The threshold
is specified in cells. A cell is 64 bytes. The range is 1 to
61,440 cells; the default is 58,000.