Urz suspension condition, 7 urz suspension condition, Suspension condition – HP StorageWorks XP Remote Web Console Software User Manual
Page 50
Table 6 Consistency Status for Suspended URz Secondary Data Volumes
Consistency
Status
Description
Volume
This URz volume pair was suspended alone. Update sequence consistency between
this secondary data volume and other secondary data volumes in this journal group is
not ensured. This secondary data volume cannot be used for disaster recovery at the
secondary system. This status is indicated when:
•
This volume pair was suspended by a user-initiated suspend pair operation with
the URz Suspend option set to Volume.
•
This volume pair was suspended due to a failure that did not affect the entire
consistency group, and the Error Level pair option for this pair is set to Volume.
Group
This URz volume pair was suspended along with the other pair in its journal group.
Update sequence consistency between this secondary data volume and other secondary
data volumes in this journal group is ensured. This secondary data volume can be used
for disaster recovery at the secondary system (after releasing the URz volume pair from
the secondary storage system). This status is indicated when:
•
This volume pair was suspended by a user-initiated suspend pair operation with
the URz Suspend option set to Group.
•
All volume pairs in this journal group were suspended due to a failure that affected
the entire journal group (not just one pair) (e.g., primary storage system-secondary
storage system communication failure).
•
The volume pair was suspended due to a failure that did not affect the entire group.
URz Suspension Condition
URz operations also involve suspension conditions related to asynchronous operations. Both the primary
storage system and secondary storage system can detect URz suspension conditions and suspend URz
pairs.
The URz suspension conditions described in
on page 50 and indicates which CU detects
the condition and which pairs are suspended. See “
” on page 201 for
troubleshooting information for URz suspension conditions.
Table 7 URz Suspension Condition
Suspension Condition
Detected by:
URz Pairs to be Suspended
The secondary storage system could not copy the
journal data successfully due to a hardware failure
or logic error.
RCU
All URz secondary data volumes in
the journal groups, or the affected
secondary data volume.
The secondary storage system detected a logical
error while selecting the journal data to be restored.
RCU
All the URz secondary data volumes
in the journal group, or only the
affected secondary data volume,
depending on the type of failure.
The secondary storage system could not restore
the journal data due to a hardware failure, track
condition, or logical error.
RCU
The primary storage system stores the differential bitmap per URz primary data volume in the shared
memory. The secondary storage system stores the differential bitmap per URz secondary data volume in
the shared memory. When a URz pair is suspended, the tracks which contain the following journal are
marked in the differential bitmap as modified (to be copied during the resume pair operation):
•
The journal data that were created by the primary storage system but not yet sent to the secondary
storage system.
After marking these primary data volume tracks as modified, the primary storage system discards
these journal data.
•
The journal data that were sent to the secondary storage system but not acknowledged by the
secondary storage system.
50
Overview of Universal Replicator Operations