beautypg.com

Configuring port attributes, Configuring port attributes – HP StorageWorks XP Remote Web Console Software User Manual

Page 112

background image

• PCB Mode displays the mode of the port. The mode is either Standard, High or MIX.
• Error Code displays an error code.

Configuring Port Attributes

The administrator at both the primary site and the secondary site must configure ports on the primary

storage system and the secondary storage system in the following ways:

The administrator at the primary site must configure target ports, initiator ports, and RCU target

ports on the primary storage system.

The administrator at the secondary site must configure initiator ports and RCU target ports on the

secondary storage system.

Ports on XP storage system have the target attribute by default. If you are configuring XP storage

systems, you must determine ports that should be used as initiator ports or RCU target ports, and then

you must change the attribute of the ports from target to initiator or RCU target. The port attributes

are explained below:

Target: A target port is a Fibre Channel port used for connecting a storage system and a host.

When the host issues a write request, the request will be sent to a volume via a target port on the

storage system. Target ports must be configured on primary storage systems for URz operations.

Initiator: An initiator port is a Fibre Channel port that sends commands to a remote storage system.

Initiator ports must be configured on both primary and remote storage systems for URz operations.

RCU target: An initiator port is a Fibre Channel port that receives commands from a remote

storage system. RCU target ports must be configured on both primary and remote storage systems

for URz operations.

External: An external port is a port that is required for Universal Volume Manager copy

operations. This port will not be used for URz copy operations.
If necessary, you can change this port to an target port, an initiator port, or an RCU target port.

Initiator/external: This setting shows the combination of ports that have an initiator port and an

external port attributes. Only port that has an initiator port attribute within these ports can be used

for URz. This attribute cannot be changed by the URz software. For details on the port to which an

initiator/external mix mode is set, please refer to the XP External Storage Software user’s guide.

If initiator ports and RCU target ports are not configured on both primary and remote storage systems, the

following problem will occur and remote copy operations will not be performed:

The administrator at the primary site will be unable to create any pair of a primary data volume

and a secondary data volume.

The secondary storage system will be unable to read data from journal volumes in the primary

storage system.

WARNING!

Before changing a Fibre Channel port to an initiator port, disconnect the port from the host, release all

affected data volume pairs, delete all logical paths from the initiator port to the remote storage system,

and then remove all channel paths to the port.

WARNING!

Before changing a Fibre Channel port from initiator to target or RCU target, delete all affected data

volume pairs, release all logical paths from the initiator port to the remote storage system, and then

disconnect the local storage system and the remote storage system.

112

Configuring Disk Storage Systems and Logical Paths

This manual is related to the following products: