HP StorageWorks XP Remote Web Console Software User Manual
Page 203
Path Status
Description
Corrective Action
Resource
Shortage (Port)
or,
Resource
Shortage
(Pair-Port)
The local and remote storage
system rejected the request
for creating a logical path
because all resources in the
local and remote storage
systems are being used for
other connections.
Delete the failed path, and also delete all paths and
remote storage systems not currently in use. The local
storage system can be connected to up to 64 remote
storage systems with up to eight paths to each remote
storage system.
Make sure all local and remote storage system ports
are properly configured: ordinary target ports or RCU
target ports for hosts, RCU target ports for remote storage
systems, initiator ports for local storage systems.
If necessary, connect to the remote storage system to delete
paths or remote storage systems and reconfigure ports,
then reconnect to the local storage system. After that, add
the path or the remote storage system again by using the
Add Path window or the Add DKC window.
Serial Number
Mismatch
The serial number (S/N) of
the remote storage system
does not match the specified
serial number (S/N).
Make sure that you entered the correct remote storage
system S/N and path parameters (e.g., local storage
system port, remote storage system port, and controller ID).
After that, delete the failed path. You may need to change
the minimum paths setting or delete the remote storage
system in order to delete the path. After deletion finishes,
add the path and the remote storage system again by
using the Add Path window or the Add DKC window.
Make sure that you entered the correct controller ID, and
also make sure that the topology settings of the local and
remote storage system ports are correct.
Invalid Port
The specified port is not
configured as an RCP or
initiator port, or this path
already exists.
Make sure that the topology settings of the local and
remote storage system ports are correct.
Make sure that you entered the correct remote storage
system S/N and path parameters (e.g., local storage
system port, remote storage system port, and controller ID).
After that, delete the failed path. You may need to change
the minimum paths setting or delete the remote storage
system in order to delete the path. After deletion finishes,
add the path and the remote storage system again by
using the Add Path window and the Add DKC window.
This path was not
established.
Delete the failed path. You may need to change the
minimum paths setting or delete the remote storage system
in order to delete the path. After deletion finishes, add the
path and the remote storage system again by using the
Add Path window and the Add DKC window.
Pair-Port Number
Mismatch
The specified port in the
remote storage system is
physically disconnected from
the local storage system.
Make sure that you specified the correct remote storage
system port. Correct the port number if necessary.
Make sure that the local storage system port and the
remote storage system port are connected via cables to
each other. If the storage systems are not connected via
cables, please connect them via cables and then retry the
operation.
Make sure that the topology settings of ports on the local
and remote storage systems are correct.
Pair-Port Type
Mismatch
The specified port in the
remote storage system is not
configured as an RCU Target
port.
Make sure that the specified port in the remote storage
system is configured as an RCU target port. Configure the
port as an RCU target port if it is not configured that way.
Communication
Failed.
The local storage system
is connected to the remote
storage system successfully,
but logical communication
timeout occurred.
Make sure that the remote storage system port and network
relay devices (e.g., cables and switches) are properly
configured and functioning.
Hitachi Universal Replicator for z/OS user guide for XP12000/XP10000 Disk Arrays and SVS 200