beautypg.com

5 suspend types – HP StorageWorks XP Remote Web Console Software User Manual

Page 49

background image

Table 7

on page 50 lists and describes the consistency status descriptions for suspended URz secondary

data volumes.
When a URz pair is suspended, whether user-requested or due to failure, the primary storage system

generates sense information to notify the host(s).

Table 5 Suspend Types

Suspend

Type

Applies to

Description

Secondary

data volume

by operator

Primary data

volume, secondary

data volume

The user suspended the pair from the primary storage system or

secondary storage system using the secondary data volume option.

By MCU

Secondary data

volume

The secondary storage system received a request from the primary

storage system to suspend the volume pair. The primary data volume

suspend type is Primary data volume by Operator or Secondary data

volume by Operator.

By RCU

Primary data

volume

The primary storage system detected an error condition at the

secondary storage system which caused the primary storage system to

suspend the URz volume pair. The secondary data volume suspend

type is By MCU.

Delete Pair to

RCU

Primary data

volume

The primary storage system detected that the secondary data volume

status changed to simplex because the user released the pair from the

secondary storage system. The pair cannot be resumed because the

secondary data volume does not have the suspended status.

Secondary

Data Volume

Failure

Primary data

volume

The primary storage system detected an error during communication

with the secondary storage system or an I/O error during update

copy. In this case, the secondary data volume suspend type is usually

By MCU.

MCU IMPL

Primary data

volume, secondary

data volume

The primary storage system could not find valid control information

in its nonvolatile memory during the IMPL procedure. This condition

occurs only if the primary storage system is completely without power

for more than 48 hours (e.g., power failure and fully discharged

backup batteries).

Initial Copy

failed

Primary data

volume, secondary

data volume

The volume pair was suspended before the initial copy operation was

complete. The data on the secondary data volume is not identical to

the data on the primary data volume.

JNL Cache

Overflow

Primary data

volume, secondary

data volume

The data volume pair was suspended because it was highly likely that

journal data will overflow.

MCU P/S

OFF

Secondary data

volume

The primary storage system is powered off.

Hitachi Universal Replicator for z/OS user guide for XP12000/XP10000 Disk Arrays and SVS 200

49

This manual is related to the following products: