33 troubleshooting suspended urz pairs, Table 33 – HP StorageWorks XP Remote Web Console Software User Manual
Page 204
Path Status
Description
Corrective Action
Port Number
Mismatch
The specified port number
is not correct, or the cable
is not connected to the
specified port.
Delete the error path.
Check the specified port number or cable connections,
and then retry the operation.
Communication
Error
A timeout error has occurred
in the fibre path between
the local and remote storage
systems.
Delete the failed path and retry.
Logical Blockade A failure occurs at a local
storage system port.
Repair the port status on the local storage system.
A failure occurs at a remote
storage system port.
Repair the port status on the remote storage system. After
that, delete the path by using the Delete Path or Delete
DKC command, and then add the path and the remote
storage system again by using the Add Path or Add DKC
command.
A failure occurs in the path
relay equipment.
Repair the path relay equipment. After that, delete the
path by using the Delete Path or Delete DKC command,
and then add the path and the remote storage system
again by using the Add Path or Add DKC command.
The connection cable is
physically broken.
Replace the broken cable. After that, delete the path by
using the Delete Path or Delete DKC command, and then
add the path and the remote storage system again by
using the Add Path or Add DKC command.
Program Error
Program error is detected.
Delete the path by using the Delete Path or Delete DKC
command, and then add the path and the remote storage
system again by using the Add Path or Add DKC command.
Table 33 Troubleshooting Suspended URz Pairs
Sus
pend
Type
Applies
to
Description
Corrective Action
Sec
ondary
Data
Volume
by Op
erator
Primary
data vol
ume,
sec
ondary
data vol
ume
The user suspended the pair from the
primary or the secondary storage system by
using the secondary data volume option.
Restore the pair from the primary
storage system.
by RCU Primary
data
volume
The primary storage system suspended a
pair because the primary storage system
detected an error condition at the secondary
storage system.
Clear the error condition at the
secondary storage system or
secondary data volume. If you need
to access the secondary data volume,
release the pair from the secondary
storage system. If any data on the
secondary data volume has changed,
release the pair from the primary
storage system and then re-create
the pair (Add Pair). If data on the
secondary data volume has not
changed, restore the pair from the
primary storage system.
204 Troubleshooting