Canon VB-C60 User Manual
Page 141

4-61
Set Preset Tour
R
e
gi
ste
r C
a
m
e
ra
Se
rv
er
and
Set
R
e
co
rdi
ng
Sche
du
le
Note
If the following warning appears, change the settings according to the tables below.
Warning example
Click [Cancel] to return to the setting screen.
Click [OK] to save the current settings.
(If you are using the Preset Setting Tool, click [Save] on the setting page of the tool)
Endurance of VB-C50i and VB-C300's pan/tilt mechanisms are approximately 100,000 round trips* at the
full range. The total tour time depends on the combination of the movement rate, movement range, and still
time. See the following tables.
Total tour time for 100,000 round trips in the pan direction (estimated).
Example: If the movement rate (PT) is 1, still time is 30 seconds, and movement range (angle) in the pan
direction is 50 degrees, it takes approximately 9,444 hours for 100,000 round trips in the pan
direction.
Endurance of VB-C60's pan/tilt mechanism is approximately 300,000 round trips* at the full range.
Total tour time for 300,000 round trips in the pan direction (estimated).
* According to our company's estimations.
Movement rate (PT) is 1.
Still time
Movement range in the
pan direction (angle)
0
10
20
30
50
3872
5666
7555
9444
±
100
3825
4722
5666
6611
150
3809
4407
5037
5666
±
(Unit: Time)
(sec.)
±
0
10
20
30
50
1983
3777
5666
7555
100
1936
2833
3777
4722
150
1920
2518
3148
3777
Movement rate (PT) is 2.
Still time
Movement range in the
pan direction (angle)
(Unit: Time)
(sec.)
±
±
±
Movement rate (PT) is 1.
Still time
Movement range in the
pan direction (angle)
0
10
20
30
50
11616
17000
22666
28333
±
100
11475
14166
17000
19833
150
11427
13222
15111
17000
±
(Unit: Time)
(sec.)
±
Movement rate (PT) is 2.
Still time
Movement range in the
pan direction (angle)
0
10
20
30
50
5950
11333
17000
22666
±
100
5808
8500
11333
14166
150
5761
7555
9444
11333
±
(Unit: Time)