Level – West Control Solutions Pro-16 User Manual
Page 39

Configuration
level
9499-040-93811 / 59537-1
Page 39 of 88
Pro-16
1 °C
2 °F
dP
Decimal point (max. number of digits behind the decimal
point)
0
0
no digit behind the decimal point
1
1 digit behind the decimal point
2
2 digits behind the decimal point
3
3 digits behind the decimal point
C.dEl
0..200
Modem delay [ms] Additional delay time before the received
message is evaluated in Modbus. This time is needed by the
modem if messages are not transferred continuously.
0
FrEq
Switching 50 Hz / 60 Hz (only visible with BlueControl
®
!)
0
0 50
Hz
1 60
Hz
MASt
Modbus Master / Slave (only visible with BlueControl
®
!)
0
0 No
1 Yes
Cycl
0 ... 240
Mastercycle (sec.) (only visible with BlueControl
®
!)
120
Adr0 -32768 ... 32767 Destination address (only visible with BlueControl
®
!)
1100
AdrU -32768 ... 32767 Source address (only visible with BlueControl
®
!)
1100
Numb
0 ... 100
Number of data (only visible with BlueControl
®
!)
1
ICof
Block controller off (only visible with BlueControl
®
!)
0
0 Released
1 Blocked
IAda
Block auto tuning (only visible with BlueControl
®
!)
0
0 Released
1 Blocked
IExo
Block extended operating level (only visible with
BlueControl
®
!)
0
0 Released
1 Blocked
ILat
Suppression error storage (only visible with BlueControl
®
!)
0
0 No
1 Yes
pTmp
Access temporary program changes (only visible with
BlueControl
®
!)
0
0 No
1 Yes