Level – West Control Solutions Pro-16 User Manual
Page 37

Configuration
level
9499-040-93811 / 59537-1
Page 37 of 88
Pro-16
8 Limit
2
9 Limit
3
Err.r
Reset of all error list entries
0
0
no function (switch-over via interface is possible)
2 DI1
3 Di
2
4
DI3 (only visible with OPTION)
5
DI4 (only visible with OPTION)
6
è -Key function (see chapter 3.6 page 14)
7 Limit
1
8 Limit
2
9 Limit
3
booS
Boost function: setpoint increases by SP.bo for the time t.bo
0
0
no function (switch-over via interface is possible)
2 DI1
3 Di
2
4
DI3 (only visible with OPTION)
5
DI4 (only visible with OPTION)
6
è -Key function (see chapter 3.6 page 14)
7 Limit
1
8 Limit
2
9 Limit
3
Pid.2
Switching of parameter set (Pb, ti, td)
0
0
no function (switch-over via interface is possible)
2 DI1
3 Di
2
4
DI3 (only visible with OPTION)
5
DI4 (only visible with OPTION)
6
è -Key function (see chapter 3.6 page 14)
7 Limit
1
8 Limit
2
9 Limit
3
P.run
Programmer Run/Stop (see page )
0
0
no function (switch-over via interface is possible)
2 DI1
3 Di
2
4
DI3 (only visible with OPTION)
5
DI4 (only visible with OPTION)