beautypg.com

Technical data, 2 technical data – KROHNE OPTISONIC 7300 EN User Manual

Page 91

background image

TECHNICAL DATA

8

91

OPTISONIC 7300

www.krohne.com

09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en

8.2 Technical data

INFORMATION!

The following data is provided for general applications. If you require data that is more
relevant to your specific application, please contact us or your local sales office.

Additional information (certificates, special tools, software,...) and complete product
documentation can be downloaded free of charge from the website (Download Center).

Measuring system

Measuring principle

Ultrasonic transit time

Application range

Flow measurement of dry gases

Measured value

Measured value

Measured value

Measured value

Primary measured value Transit time

Secondary measured

values

Volume flow, corrected volume flow, mass flow, molar mass, flow speed, flow

direction, speed of sound, gain, signal to noise ratio, reliability of flow

measurement, quality of acoustic signal

Design

Features

1 or 2 path all welded flow sensor with o-ring fitted titanium transducers.

Modular construction

The measurement system consists of a measuring sensor and a signal

converter.

Compact version

OPTISONIC 7300 C

Remote version

OPTISONIC 7000 F with GFC 300 F signal converter

Nominal diameter

1 path: DN50...80 / 2...3"

2 path: DN100...600 / 4"...24"

Larger diameters on request.

Measurement range

-30... +30 m/s / -98.4... +98.4 ft/s

Signal converter

Signal converter

Signal converter

Signal converter

Inputs / outputs

Current (incl. HART

®

), pulse, frequency and/or status output, limit switch

and/or control input (depending on the I/O version)

Counters

2 internal counters with a max. of 8 counter places

(e.g. for counting volume and/or mass units).

Self diagnostics

Integrated verification, diagnosis functions: flowmeter, process,

measured value, bargraph

Communication

interfaces

Modbus, HART

®

, FF