beautypg.com

Operation – KROHNE OPTISONIC 7300 EN User Manual

Page 79

background image

OPERATION

6

79

OPTISONIC 7300

www.krohne.com

09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en

C5.1.4

electronic serial no.

Serial no. of the electronic assembly, can not be changed.

C5.1.5

SW.REV.MS

1

st

line: serial number of the I/O circuit board

2

nd

line: software version number

3

rd

line: production date of the circuit board

C5.1.6

Electronic Revision

ER

1

st

line: serial number of the I/O circuit board

2

nd

line: software version number

3

rd

line: production date of the circuit board

C5.2

display

C5.2.1

language

Select: English / Français / Deutsch

C5.2.2

contrast

Adjust display contrast for extreme temperatures.

Setting: -9…+9

Change is immediate!

C5.2.3

default display

Specification of the default display page that is returned to after a

short delay period.

Select: none (the current page is always active) / 1. meas. page (show

this page) / 2. meas. page (show this page) / status page (show only

status messages) / graphic page (trend display of the
1

st

measurement)

C5.2.5

SW.REV.UIS

Software Revision User Interface Software

1

st

line: serial number of the I/O circuit board

2

nd

line: software version number

3

rd

line: production date of the circuit board

C5.3

1. meas. page

…

stands for:

3 = meas. page 1

C5.4

2. meas. page

4 = meas. page 2

C5.….1

function

Specify number of measured value lines (font size).

Select: one line / two lines / three lines

C5.….2

measurement 1.line

Specify measurement for 1

st

line.

Select: volume flow / corr. volume flow / mass flow / molar mass / flow

speed / velocity of sound / gain / diagnostics 1, 2, 3

C5.….3

range

0…100% of the measurement set in Fct. C5.….2.

0…xx.xx _ _ _ (format and unit depend on the measurement)

C5.….4

limitation

Set lower and upper limit for frequency output before applying the time

constant.

xxx%

Range: -120…+120%

C5.….5

low flow cutoff

Sets output to "0".

x.xxx ± x.xxx %

Range: 0.0…20%

1

st

value = switching point / 2

nd

value = hysteresis

Condition: 2

nd

value ≤ 1

st

value

C5.….6

time constant

Averages measurement

Increasing value improves stability but delays the reaction.

Range: 0.1…100 s