Description of hart interface, 7 diagnostic root menu, Status – KROHNE OPTISONIC 7300 EN User Manual
Page 125
DESCRIPTION OF HART INTERFACE
9
125
OPTISONIC 7300
www.krohne.com
09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en
9.11.7 Diagnostic Root Menu
Status
Standard
Device status
Rd
Primary variable outside the operation limits
Non-primary variable outside the operation limits
Analog output outside the operating range limits
Analog output in fixed mode
More status available
Cold start occured
Configuration changed
Field device malfunctioned
Write Protect
Rd
Failure (device)
Failure (device) 1
Failure (device) 1
Failure (device) 1
Failure (device) 1
Rd
Rd
Rd
Rd
F error in device / F IO1 / F parameter / F IO2 / F configuration / F display /
F current in-/output A / F current in-/output B /
Failure (device) 2
Failure (device) 2
Failure (device) 2
Failure (device) 2
Rd
Rd
Rd
Rd
F current output C / F software user interface / F hardware settings /
F hardware detection / F RAM/ROM error IO1 / F RAM/ROM error IO2 / F Fieldbus
Failure (device) 3
Failure (device) 3
Failure (device) 3
Failure (device) 3
Rd
Rd
Rd
Rd
F communication dsp-up / F sensor driver / F uProc. / F dsp / F parameter frontend
Failure (application)
Failure (application) 1
Failure (application) 1
Failure (application) 1
Failure (application) 1
Rd
Rd
Rd
Rd
F application error / F open circuit A / F open circuit B / F open circuit C /
F over range A (current) / F over range B (current) / F over range C / F over range A (pulse)
Failure (application) 2
Failure (application) 2
Failure (application) 2
Failure (application) 2
Rd
Rd
Rd
Rd
F over range B (pulse) / F over range D / F active settings / F factory settings /
F backup 1 settings / F backup 2 settings / F wiring A (output) / F wiring B (output)
Failure (application) 3
Failure (application) 3
Failure (application) 3
Failure (application) 3
Rd
Rd
Rd
Rd
F wiring A (input) / F wiring B (input) / F flow exceeding limit / F signal lost path 1 /
F signal lost path 2 / F signal lost path 3
Failure (application) 4
Failure (application) 4
Failure (application) 4
Failure (application) 4
Rd
Rd
Rd
Rd
F transducer delay / F temperature input / F pressure input / F p&t input / F VoS monitor
Out of specification
Out of specification 1
Out of specification 1
Out of specification 1
Out of specification 1
Rd
Rd
Rd
Rd
S out of specification / S overflow counter 1 (C) / S overflow counter 1 (B) /
S overflow counter 2 / S overflow counter 3 / S backplane invalid /
S error current A / S error current B
Out of specification 2
Out of specification 2
Out of specification 2
Out of specification 2
Rd
Rd
Rd
Rd
S unreliable 1 / S unreliable 2 / S unreliable 3 / S front end calibration / S dsp timing error
Check function &
Information
Check function
Check function
Check function
Check function
Rd
Rd
Rd
Rd
C checks in progress / C simulation flow / C simulation VoS / C simulation fieldbus
Information 1
Information 1
Information 1
Information 1
Rd
Rd
Rd
Rd
I counter 1 stopped (C) / I counter 1 stopped (B) / I counter 2 stopped / I counter 3 stopped /
I power fail / I control input A active / I control input B active / I over range display 1
Information 2
Information 2
Information 2
Information 2
Rd
Rd
Rd
Rd
I over range display 2 / I backplane sensor / I backplane settings /
I backplane difference / I optical interface
Information 3
Information 3
Information 3
Information 3
Rd
Rd
Rd
Rd
I start up