TECHNICAL DATA
8
101
OPTISONIC 7300
www.krohne.com
09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en
FOUNDATION Fieldbus
FOUNDATION Fieldbus
FOUNDATION Fieldbus
FOUNDATION Fieldbus
Discription
Galvanically isolated acc. to IEC 61158
Current consumption: 10.5 mA
Permisseble bus voltage: 9...32 V; in Ex application 9...24 V
Bus interface with integrated reverse polarity protection
Link Master function (LM) supported
Tested with Interoperable Test Kit (ITK) version 5.2
Function blocks
6 x analoque input, 2 x integrator, 1 x PID, 1 x arithmetic
Output data
Volume flow, corr. volume flow, mass flow, molar mass, enthalpy flow,
spec. enthalpy, density, flow speed, process temperature, process pressure,
electronic temperature, velocity of sound (av.), gain (av.), SNR (av.),
velocity of sound 1-3, gain 1-3, SNR 1-3
MODBUS
MODBUS
MODBUS
MODBUS
Description
Modbus RTU, Master / Slave, RS485 (galvanically isolated)
Transmission procedure
Half duplex, asynchronous
Address range
1…247
Supported function
codes
01, 03, 04, 05, 08, 16, 43
Broadcast
Supported with function code 16
Supported Baudrate
1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 Baud
Approvals and certificates
CE
CE
CE
CE
This device fulfills the statutory requirements of the EC directives.
The manufacturer certifies successful testing of the product by applying the
CE mark.
Electromagnetic
compatibility
Directive: 2004/108/EC, NAMUR NE21/04
Harmonized standard: EN 61326-1 : 2006
Low Voltage Directive
Directive: 2006/95/EC
Harmonized standard: EN 61010 : 2001
Pressure Equipment
Directive
Directive: 97/23/EC
Category I, II, III or SEP
Fluid group 1
Production module H
Other approvals and standards
Other approvals and standards
Other approvals and standards
Other approvals and standards
Non-Ex
Standard
Hazardous areas
Hazardous areas
Hazardous areas
Hazardous areas
For detailed information, please refer to the relevant Ex documentation.
ATEX
PTB 10 ATEX 1052
Protection category acc.
to IEC 529 / EN 60529
Signal converter
Signal converter
Signal converter
Signal converter
Compact (C): IP66/67 (NEMA 4X/6)
Field (F): IP66/67 (NEMA 4X/6)
All flow sensors
All flow sensors
All flow sensors
All flow sensors
IP67 (NEMA 6)
Shock resistance
IEC 68-2-27
Vibration resistance
IEC 68-2-64