DESCRIPTION OF HART INTERFACE

9

127

OPTISONIC 7300

www.krohne.com

09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en

9.11.8 Device Root Menu

Quick Setup

Quick Setup

Quick Setup

Quick Setup

Quick Setup

Language / Tag / Polling Address /

Opt

Reset Counter 1 / Reset Counter 2 / Reset Counter 3

Opt

Detailed Setup

Detailed Setup

Detailed Setup

Detailed Setup

Process Input

Calibration

Meter Size / / GK

Filter

Minimum Limit / Maximum Limit / Flow Direction / Time Constant /

Threshold Low Flow Cutoff / Hysteresis Low Flow Cutoff

Plausibility

Error Limit / Counter Decrease / Counter Limit

Simulation

/

Information

/ / / /

/ Serial Number Sensor / V Number Sensor

VoS monitor

Opt

Monitor Velocity of Sound

Monitor Settings

Monitor Settings

Monitor Settings

Monitor Settings

Opt

Opt

Opt

Opt

Matching Factor / Actual Ratio Measurement/Calibration / /

VoS Tolerance / Time Constant

Linearization

Linearization / Dynamic Viscosity

Opt

General

Opt

Adiabatic Index

P&T Correction

Opt

P&T Correction / / P&T Inputs

Opt

/ Pipe Temperature

Opt

/

Pipe Pressure

Opt

/ Density

Opt

Diagnosis Value

Diagnosis 1 / / Diagnosis 2 / / Diagnosis 3 /

HART

Sensor s/n /

Actual Flow, Corrected Flow

Actual Flow, Corrected Flow

Actual Flow, Corrected Flow

Actual Flow, Corrected Flow

Opt

Opt

Opt

Opt

, Enthalpy Flow

Enthalpy Flow

Enthalpy Flow

Enthalpy Flow

Opt

Opt

Opt

Opt

, Mass Flow ,

, Mass Flow ,

, Mass Flow ,

, Mass Flow ,

Unit / Format / Upper Sensor Limit / Lower Sensor Limit / Minimum Span

I/O

Hardware

Terminals A / Terminals B / Terminals C / Terminals D

Current Output A/B/C

Opt

Range 0%

Cust

/ Range 100%

Cust

/ Extended Range Min

Cust

/ Extended Range Max

Cust

/

Error Current

Cust

/ Error Condition

Cust

/ Measurement

Cust

/ Range Min

Cust

/

Range Max

Cust

/ Polarity

Cust

/ Limitation Min

Cust

/ Limitation Max

Cust

/

LFC Threshold

Cust

/ LFC Hysteresis

Cust

/ Time Constant

Cust

/ Special Function

Cust

/

Threshold Range Change

Opt, Cust

/ Hysteresis Range Change

Opt, Cust

/ /

Frequency Output
A/B/D

Opt

Pulse Shape

Opt, Cust

/ Pulse Width

Opt, Cust

/ 100% Pulse Rate

Opt, Cust

/ Measurement

Cust

/

Range Min

Cust

/ Range Max

Cust

/ Polarity

Cust

/ Limitation Min

Cust

/

Limitation Max

Cust

/ LFC Threshold

Cust

/ LFC Hysteresis

Cust

/ Time Constant /

Invert Signal

Cust

/ Special Function

Opt, Cust

/ Phase Shift

Opt, Cust

/ /

Pulse Output A/B/D

Opt

Pulse Shape

Opt, Cust

/ Pulse Width

Opt, Cust

/ Max. Pulse Rate

Opt, Cust

/ Measurement

Cust

/

Pulse Value Unit

Rd, Cust

/ Value Per Pulse

Cust

/ Polarity

Cust

/ LFC Threshold

Cust

/

LFC Hysteresis

Cust

/ Time Constant / Invert Signal

Cust

/ Special Function

Opt, Cust

/

Phase Shift

Opt, Cust

/ /