beautypg.com

Description of hart interface – KROHNE OPTISONIC 7300 EN User Manual

Page 129

background image

DESCRIPTION OF HART INTERFACE

9

129

OPTISONIC 7300

www.krohne.com

09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en

HART

HART

HART

Rd

/ Online Mode?

Loc

/

Identification

Identification

Identification

Identification
Polling address / Tag / Manufacturer

Rd

/ Model

Rd

/ Device ID

Rd

HART Revisions

HART Revisions

HART Revisions

HART Revisions
Universal revision

Rd

/ Field device revision

Rd

/ DD version

Rd

Device Info

Device Info

Device Info

Device Info

Descriptor / Message / Date / Final assembly number /
Software revision / Hardware revision / Write Protect

Rd

Preambles

Preambles

Preambles

Preambles
Number of request preambles

Rd

/ Number of response preambles

Service

Service

Service

Service

Service Access

Access Level HART

Rd

/ /

Opt

Signal Data

Opt

Signal Data

Transducer Type / Window Start / Window End / Pulse Form / Detection Method

Detection Parameters

Detection Parameters

Detection Parameters

Detection Parameters

Trigger Level / Trigger Margin / Envelope Margin / Peak Margin / Number Of Peaks /

Envelope Ratio 1 / Envelope Ratio 2 / Envelope Ratio 3 / Envelope Ratio 4 / RelmaxLow /

RelmaxHigh / MaxTrackFactor / MaxTrackOffset / MaxTrackLimit / MaxTrackHit /

MaxTrackLim / XcorrActive / / Fixed Gain / Xdetect /

GainUnbalWarning / GainUnbalSigLost / XdetSNRLimit / XdetAverageNo /

SNRLimSigLost / SNRLimWarning / Env. Shift monitor / Env. Ratio monitor

Dead Time /

Delay Test

Delay Test

Delay Test

Delay Test
Mode / Act. Delay T1.1

Opt

/ Act. Delay T1.2

Opt

/ Act. Delay T2.1

Opt

/ Act. Delay T2.2

Opt

/

TD Trigger Level

Opt

/ TD Trigger Margin

Opt

/ TD Window Start

Opt

/ TD Window End

Opt

/

TD Dead Time

Opt

/ Repetition Pings

Opt

Number Of Stacks / Number Of Bursts / Burst Period / Ping Time /

Step-Up Voltage /

Path Data

Opt

Path Data

Number Of Paths / Velocity Of Sound / / Path Length 1 /

Path Length 2 / Path Length 3 / Weight 1 / Weight 2 / Weight 3 / Beam Angle /

T Expansion Coeff. / P Expansion Coeff. / Transducer Compression

Service Calibration

Opt

Service Calibration

Front End Option

Rd

Zero Instrument

Zero Instrument

Zero Instrument

Zero Instrument

Zero Offset Path 1 / Zero Offset Path 2 / Zero Offset Path 3

Zero Converter

Zero Converter

Zero Converter

Zero Converter
Path 1

Rd

/ Path 2

Rd

/ Path 3

Rd

Service Info

Opt

Service Info

Detected C-No.

Rd

/ C-Number (8th Position)

Rd

/ Device Serial Number

Rd

/

Serial Number Sensor

Rd

/ V Number Sensor

Rd