beautypg.com

Operation – KROHNE OPTISONIC 7300 EN User Manual

Page 69

background image

OPERATION

6

69

OPTISONIC 7300

www.krohne.com

09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en

C1.5.2

velocity of sound

Query: sim. velocity of sound.

Select: cancel / set value

Range: 200.00…1100.0 (start simulation? yes / no)

C1.6

information

C1.6.1

sensor CPU

Identification of hardware and software for flow processing.

1

st

line: ID No. of the circuit board

2

nd

line: software version

3

rd

line: production date

C1.6.2

sensor DSP

Identification of hardware and software for signal processing.

1

st

line: ID No. of the circuit board

2

nd

line: software version

3

rd

line: production date

C1.6.3

sensor driver

Identification of hardware and software for driver part.

1

st

line: ID No. of the circuit board

2

nd

line: software version

3

rd

line: production date

C1.9

linearization

Correction for non linear deviations of the output.

Select: start sequence C1.9.1

C1.9.1

linearization

Select: on / off

C1.9.2

dynamic viscosity

Only availabale if 'on' is selected in C1.9.1

Select value

Range: 0.500...50.00 µPa.s

C1.10

adiabatic index

Value for adiabatic index.

Select value

Range: 1.0000…2.0000

C1.11

P & T correction

Compensation for thermal and pressure expansion of the sensor.

Select: Normal / None / OPEC / IUPAC / Old Normal

(activates options C1.12 to C1.15)

Calculation of gasflow to standard conditions using input of a

temperature and a pressure transmitter.

P&T correction Normal: calculation to 0°C and 101,325 kPa,

(DIN 1343)

P&T correction Old Normal: calculation to 15°C, 101,325 kPa,

(ISO 13443)

P&T correction IUPAC: calculation to 0°C and 100 kPa

P&T correction OPEC: calculation to 60°F and 14.73 psi

Compensation of flow tube expansion / contraction due to temperature

and pressure variation.

Before entering C1.15 (density) first save the setting and leave the

menu.

C1.12

P & T inputs

Select: automatic / fixed

Automatic: using input from connected pressure and temperature

transmitters

Fixed: manual fixed temperature and pressure setting via menu option

C1.13 / C1.14