ELECTRICAL CONNECTIONS

4

41

OPTISONIC 7300

www.krohne.com

09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en

4.7.4 Modular inputs/outputs and bus systems

Current output active (only current output terminals C/C- have HART

®

capability),

modular I/Os

• U

int, nom

= 24 VDC

• I ≤ 22 mA
• R

L

≤ 1 kΩ

• X designates the connection terminals A, B or C, depending on the version of the signal

converter.

Current output passive (only current output terminals C/C- have HART

®

capability),

modular I/Os

• U

ext

≤ 32 VDC

• I ≤ 22 mA
• U

0

≥ 1.8 V

• R

L, max

= (U

ext

- U

0

) / I

max

• X designates the connection terminals A, B or C, depending on the version of the signal

converter.

CAUTION!
Observe connection polarity.

INFORMATION!

For further information on electrical connection refer to Description of the inputs and outputs
on page 31

.

For the electrical connection of bus systems, please refer to the separate documentation for
the respective bus systems.

Figure 4-11: Current output active I

a

Figure 4-12: Current output passive I

p