beautypg.com

Electrical connections – KROHNE OPTISONIC 7300 EN User Manual

Page 46

background image

4

ELECTRICAL CONNECTIONS

46

OPTISONIC 7300

www.krohne.com

09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en

Status output / limit switch S

N

NAMUR, modular I/Os

• Any connection polarity.
• Connection in conformity with EN 60947-5-6
• open:

I

nom

= 0.6 mA

closed:
I

nom

= 3.8 mA

• The output is open when the device is de-energized.
• X designates the connection terminals A, B or D, depending on the version of the signal

converter.

Control input active, modular I/Os

• U

int

= 24 VDC

• External contact open:

U

0, nom

= 22 V

External contact closed:
I

nom

= 4 mA

• Switching point for identifying "contact open or closed":

Contact open (off): U

0

≤ 10 V with I

nom

= 1.9 mA

Contact closed (on): U

0

≥ 12 V with I

nom

= 1.9 mA

• X designates the connection terminals A or B, depending on the version of the signal

converter.

Figure 4-18: Status output / limit switch S

N

to NAMUR EN 60947-5-6

CAUTION!
Observe connection polarity.

Figure 4-19: Control input active C

a

1 Signal