Brocade FastIron SX Series Chassis Hardware Installation Guide User Manual
Page 98
Chassis status and temperature information (Continued)
TABLE 21
Field
Definition
Fan status
The status of a fan can be one of the following:
•
OK - The fan is functioning properly and is keeping the temperature of each module
within an acceptable temperature range.
•
Failed - The fan is not functioning properly or the fan control module cannot control the
fan.
Speed Operating
mode
The operating mode of a fan can be one of the following:
•
Auto (automatic) - This is the default
•
Manual
Current fan speed
The fan speed for the FSX 800 can be one of the following:
•
1 (low) - The fan is functioning at 25 percent of capacity.
•
2 (medium-low) - The fan is functioning at 37 percent of capacity.
•
3 (medium) - The fan is functioning at 50 percent of capacity.
•
4 (high) - The fan is functioning at 100 percent of capacity.
The current fan speed is shown in double brackets.
Temperature
Fan controlled
temperature
The FSX 800 and FSX 1600 display the temperature reading of the management, interface,
and switch fabric modules:
•
Rule 1/3 - The highest temperature reading of the management module or modules.
•
Rule 2/3 - The highest temperature reading of all the interface modules.
•
Rule 3/3 - The highest temperature reading of the switch fabric modules.
Fan speed
switching
temperature
thresholds
•
The FSX 800 and FSX 1600 display the configured temperature thresholds for the
management, interface, and switch fabric modules.
•
Rule 1/3 (MGMT CARDS THERMAL PLANE) - The configured temperature thresholds
for the management module or modules.
•
Rule 2/3 - (LINE CARDS THERMAL PLANE) - The configured temperature thresholds for
all the interface modules.
•
Rule 3/3 - (SWITCH FABRIC CARDS THERMAL PLANE) - The configured temperature
thresholds for the switch fabric modules.
The output displays fan speed information for each of the above thermal planes.
The FSX 800 chassis devices has four fan speeds as illustrated in
thresholds for thermal planes and fan speeds
on page 98.
Slot number
Temperature
The temperature of each module.
•
On the FSX 800 and FSX 1600, the management modules are in slots 9 and 10 and the
switch fabric modules are SF 1 and SF 2 .
Other information
Boot PROM MAC
The MAC address of the chassis.
Managing the Chassis and Modules
96
Brocade FastIron SX Series Chassis Hardware Installation Guide
53-1003092-01