Specifying a port address, Specifying a data port, Specifying a management port – Brocade FastIron SX Series Chassis Hardware Installation Guide User Manual
Page 26: Management modules, Fsx 800 and fsx 1600 management modules
15 Interface slot 15
16 Interface slot 16
17 Management slot 17
18 Management slot 18
19 Switch fabric slot 1
20 Switch fabric slot 2
21 ESD ground connector
FIGURE 4 FSX 1600 slots
DANGER
For safety reasons, the ESD wrist strap should contain a series 1 megohm resistor.
Specifying a port address
You can specify a port address for a data port or a management port.
Specifying a data port
The port address format is slot /port , where:
•
slot --Specifies the interface slot number. Range is from 1 to 8 (FSX 800) or 1 to 16 (FSX 1600).
•
port --Specifies the port number in the slot. Range is from 1 to 48 depending on the interface
module.
This example shows how to specify port 2 in slot 1:
Brocade (config) # interface ethernet 1/2
Specifying a management port
The management port number is always 1. This example shows how to specify the management port:
Brocade (config) # interface management 1
Management modules
The FSX 800 and FSX 1600 device each require one management module and optionally support two
management modules for 100% redundancy. Each management module occupies one half slot.
FSX 800 and FSX 1600 management modules
Management modules for the FSX 800 and FSX 1600 are interchangeable between devices. Standard
management modules provide Layer 2 and base Layer 3 functionality only. Premium management
modules support full Layer 3 functionality.
Specifying a port address
24
Brocade FastIron SX Series Chassis Hardware Installation Guide
53-1003092-01