Brocade FastIron SX Series Chassis Hardware Installation Guide User Manual
Page 160
MTBF for the FastIron X Series chassis and modules (Continued)
TABLE 32
Configuration or Module
Temperature MTBF (hours)
FSX 800 + fan module + two switch fabric modules + one AC power supply
40 ° C
142,786
FSX 800 + fan module + two switch fabric modules + two AC power supplies
40 ° C
230,584
FSX 800 + one management module + fan module + two switch fabric modules +
one AC power supply
40 ° C
93,328
FSX 800 + two management modules + fan module + two switch fabric modules +
one AC power supply
40 ° C
142,786
FSX 1600
FSX 1600 + fan module + two switch fabric modules
40 ° C
213,865
FSX 1600 + fan module + two switch fabric modules + two AC power supplies
40 ° C
99,908
FSX 1600 + fan module + two switch fabric modules + four AC power supplies
40 ° C
213,865
FSX 1600 + one management module + fan module + two switch fabric modules +
two AC power supplies
40 ° C
72,883
FSX 1600 + two management modules + fan module + two switch fabric modules +
two AC power supplies
40 ° C
99,908
FSX 800 and FSX 1600 Management Modules
IPv6 2-port 10-GbE management module with no optics
40 ° C
304,109
IPv6 2-port 10-GbE management module with one optic
40 ° C
284,715
IPv6 2-port 10-GbE management module with two optics
40 ° C
267,645
IPv6 8-port GbE management module with 4 copper
40 ° C
343,272
IPv6 8-port GbE management module with 4 copper and four optics
40 ° C
262,526
IPv4 8-port GbE management module with 4 copper
40 ° C
343,272
IPv4 8-port GbE management module with 4 copper and four optics
40 ° C
262,526
IPv4 2-port 10-GbE management module with no optics
40 ° C
269,436
IPv4 2-port 10-GbE management module with one optic
40 ° C
254,100
IPv4 2-port 10-GbE management module with two optics
40 ° C
240,416
IPv4 management module with no ports
40 ° C
534,522
Hardware Specifications
158
Brocade FastIron SX Series Chassis Hardware Installation Guide
53-1003092-01