Aug 27 12:19:00:N:Module up in slot 3

Aug 27 12:18:43:I:Warm start

When you clear log entries, you can selectively clear the static or dynamic buffer, or you can clear both.
For example, to clear only the dynamic buffer, enter the following command at the Privileged EXEC
level.

device# clear logging dynamic-buffer

Syntax: clear logging [ dynamic-buffer | static-buffer ]

You can specify the dynamic-buffer keyword to clear the dynamic buffer or the static-buffer keyword
to clear the static buffer. If you do not specify a buffer, both buffers are cleared.

Syntax: show log

Syslog messages for PCI (hardware) errors

FastIron Chassis devices support the display of PCI (hardware) read and write errors encountered on a
slot or module during bootup and during normal system operations. There are four types of PCI errors,
which may cause the system to disable or power down the module or modules on which they occur:

Configuration read error

Configuration write error

Memory read error

Memory write error

For more information, refer to the “Using Syslog” chapter in the FastIron Ethernet Switch Administration
Guide
.

Managing the switch fabric modules (FSX 800 and FSX 1600 only)

If desired, you can disable power to a switch fabric module and then re-enable it. To disable the power,
enter the following command at the Privileged EXEC level of the CLI.

device

# disable switch-fabric 1

Syntax: disable switch-fabric { 1 | 2 }

where switch-fabric 1 is the left-most module in the FSX 800 chassis and the top-most module in the
FSX 1600 chassis, and switch-fabric 2 is the right-most module in the FSX 800 chassis and the
bottom-most module in the FSX 1600 chassis.

To re-enable power to the switch fabric module, enter the following command at the Privileged EXEC
level of the CLI.

device# enable switch-fabric 1

Syntax: enable switch-fabric { 1 | 2 }

where switch-fabric 1 is the left-most module in the FSX 800 chassis and the top-most module in the
FSX 1600 chassis, and switch-fabric 2 is the right-most module in the FSX 800 chassis and the
bottom-most module in the FSX 1600 chassis.