Regulatory compliance

The table below lists the Electromagnetic Compatibility (EMC), Immunity standards, and safety agency
approvals for the FastIron Chassis.

Regulatory compliance

TABLE 29

Certifications

Emissions

Canada Interference Causing Equipment Regulations

EN 55022 / CISPR-22 Class A / VCCI Class A

FCC Class A

Electromagnetic

EN 61000-3-2 Power Line Harmonics

EN 61000-4-2 ESD

EN 61000-4-3 Radiated Immunity

EN 61000-4-4 EFT

EN 61000-4-5 Surge

EN 61000-4-6 Low Frequency Common Immunity

EN 61000-4-11 Voltage Dips and Sags Generic: EN 50082-1

ESD: IEC 61000-4-2; 4 kV CD, 8 kV AD

Radiated: IEC 61000-4-3; 3 V/m

EFT/Burst: IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line)

Conducted: IEC 61000-406; 3 V

Safety Agency

CAN/CSA-C22.2 No. 60950-1-07 / UL 60950-1 - 2nd Edition, Safety of Information Technology Equipment

EN 60825-1 Safety of Laser Products - Part 1: Equipment Classification, Requirements and User’s Guide

EN 60825-2 Safety of Laser Products - Part 2: Safety of Optical Fibre Communications Systems

EN 60950-1 / IEC 60950-1 - Safety of Information Technology Equipment

Maximum power consumption

The table below lists the maximum power consumption for the modules and other components in the
Brocade chassis.

NOTE
For a list of part numbers for the Management and Interface modules, refer to the "Management
modules," "FSX 800 and FSX 1600 management modules," and "Interface modules" sections.

Maximum power consumption

TABLE 30

Hardware Component

Maximum Power
Consumption (Watts)

Maximum Number of Components
per Chassis

FSX 800

FSX 1600

Regulatory compliance

Brocade FastIron SX Series Chassis Hardware Installation Guide