Init - The module is currently initializing as the standby module.
‐
OK - The module is ready to take over as the active module, if necessary.
‐
Wait - The module is awaiting boot information from the active management module.
‐
Sync - The active module is currently synchronizing files between itself and the standby
module.
Displaying temperature information
Each management module contains two temperature sensors. By default, the system polls the
temperature of each management module every 60 seconds. You can display the current temperature
of the management modules (and all other modules) by entering the following command at any CLI
level.
device# show chassis
...
Slot 9 Temperature: 31.0 deg-C
Slot 10 Temperature: 34.0 deg-C
...
Syntax: show chassis
The output displays the temperature of the management modules.
Displaying switchover information
You can view the system log or the traps logged on an SNMP trap receiver, which includes Information
about whether a switchover has occurred. For Syslog messages related to hitless OS upgrade and
hitless switchover, refer to the FastIron Ethernet Switch Administration Guide.
To view the system log or the traps logged on an SNMP trap receiver, enter the following command at
any level of the CLI.
device# show log
Syslog logging: enabled (0 messages dropped, 0 flushes, 0
overruns)
Buffer logging: level ACDMEINW, 25 messages logged
level code: A=alert C=critical D=debugging M=emergency E=error
I=informational N=notification W=warning
Dynamic Log Buffer (50 lines):
0d14h43m52s:N:System: Module was inserted to slot 9
0d14h43m23s:N:System: Fan speed changed automatically to 3
0d14h43m23s:N:System: Fan speed changed automatically to 3
0d14h43m23s:N:System: Fan speed changed automatically to 3
0d14h43m23s:N:System: Fan speed changed automatically to 3
0d14h43m23s:N:System: Fan speed changed automatically to 3
0d14h43m23s:N:System: Fan speed changed automatically to 3
0d14h43m20s:I:System: Interface ethernet 5/2, state up
0d14h43m19s:I:System: Interface ethernet 3/2, state up
0d14h43m19s:I:System: Interface ethernet mgmt1, state up
0d14h43m19s:I:System: Interface ethernet 6/13, state up
0d14h43m18s:I:System: Interface ethernet 4/1, state up
0d14h43m18s:I:System: Interface ethernet 2/13, state up
0d14h43m18s:N:System: Fan speed changed automatically to 2
0d14h43m18s:N:System: Fan speed changed automatically to 2
0d14h43m18s:N:System: Fan speed changed automatically to 2
0d14h43m18s:N:System: Fan speed changed automatically to 2
0d14h43m18s:N:System: Fan speed changed automatically to 2
0d14h43m18s:N:System: Fan speed changed automatically to 2
0d14h43m18s:I:System: Interface ethernet 1/13, state up
0d14h43m16s:N:powered On switch Fabric
0d14h43m09s:N:powered On switch Fabric
0d14h43m01s:I:Mgmt CPU1 slot 9 failed
0d14h43m01s:I:System: Warm start
0d14h43m01s:I:SNMP: read-only community added by from session FastIron SX 800
Displaying temperature information
Brocade FastIron SX Series Chassis Hardware Installation Guide
115