Brocade FastIron SX, FCX, and ICX Diagnostic Reference User Manual
Page 44

32
Brocade FastIron SX, FCX, and ICX Diagnostic Reference
53-1003076-02
MCT debug commands
3
Brocade(config-cluster-ABC)# peer 10.10.10.1 rbridge-id 100 icl icl1
Brocade(config-cluster-ABC)# deploy
============= cluster create ===============
CLUSTER CCP:ccp_internal_create_cluster::Cluster 1 Configured.
Brocade(config-cluster-ABC)# client c1uster
Brocade(config-cluster-ABC-client-c1)# rbridge-id 300
Brocade(config-cluster-ABC-client-c1)# client-interface ethernet 4/13
=========== Client add ======================
clustercu_add_client_interface(cluseter=1,client_name=c1,client_port=4/13)
clustermgr_add_cluster_client_port(cluseter=1,client_name=c1,client_port=4/13,add
)
Brocade(config-cluster-ABC-client-c1)# deploy
===================== FSM Message ====================
clustermgr_send_loading_info_to_peer(cluster=1)(T=121842) >>>>
clustermgr_send_vlanmask_to_peer && clustermgr_send_intf_mac_to_peer
clustermgr_send_loading_info_to_peer(cluster=1)(T=121842) >>>> DONE
================ Client isolation mode config ==============
Brocade(config-cluster-ABC)# client-isolation strict
clustermgr_client_isolation_mode(cluster_id=1,mode=1)
If the debug cluster config command is disabled, the output similar to the following is displayed.
Brocade# no debug cluster config
CLUSTER Config debugging is now OFF?
debug cluster fsm
Syntax: [no] debug cluster fsm client client_id
This command enables debugging of the MCT cluster FSM for a particular client. Any events that
occur in the client such as CCEP Up/Down, remote CCEP Up/Down, or CCP Up/Down, are tracked.
The client_id variable refers to the port number of the client.
Brocade# debug cluster fsm client 300
CLUSTER fsm debugging is now ON for client rbridge 300
=================== Local CCEP Down ===================
Brocade(config-if-e1000-4/13)# disable
CLUSTER FSM: cluster id 1, client id 300, old state: Up, event: Local Down
CLUSTER FSM: new state: Remote Up, master: FALSE
Brocade(config-if-e1000-4/13)# CLUSTER FSM: Received CCRR message from peer when
CCP is up
Brocade(config-if-e1000-4/13)# enable
=================== Local CCEP UP ===================
Brocade(config-if-e1000-4/13)# CLUSTER FSM: cluster id 1, client id 300, old
state: Remote Up, event: Local Up
CLUSTER FSM: new state: Preforwarding Remote Up, master: FALSE
=================== Remote CCEP Down ===================
CLUSTER FSM: Received CCRR message from peer when CCP is up
CLUSTER FSM: cluster id 1, client id 300, old state: Preforwarding Remote Up,
event: CCRR Ack Rcvd
CLUSTER FSM: new state: Up, master: FALSE
CLUSTER FSM: Received CCRR message from peer when CCP is up
CLUSTER FSM: cluster id 1, client id 300, old state: Up, event: Remote Down
CLUSTER FSM: Cluster ABC (Id: 1), client c1 (RBridge Id: 300) - Remote client CCEP
down
CLUSTER FSM: new state: Local Up, master: FALSE