Troubleshooting

162

NXD/T-1200V 12" Modero® Video Wall/Flush Mount Touch Panel

Troubleshooting Information (Cont.)

Symptom

Solution

I updated my panel firmware but
my Battery Base page doesn’t
seem to be working properly.

• Cycle power manually to the panel and check the Battery Base page

after startup.

• If downloading the firmware to the panel via a COM port, try using an

IP Address and retry the download of the firmware to the panel.

There is a crawling, dashed line on
the left border of the graphics.

• On some units at some resolutions, there are wavy lines across the

entire screen. This has been seen on middle resolutions and is
referred to as the "Mid Range Fallout" problem.

• This is due to the graphics controller settings in the firmware.

• Update firmware to the latest v2.XX. firmware.

• Visit the www.amx.com > Tech Center > Downloadable Files >

Firmware Files > Modero panels. Then Download the KIT file to
your computer.

My Modero panel isn’t appearing
in my Workspace window.

• Verify that the System number is the same on both the NetLinx

Workspace window and the System Settings page on the Modero
panel.

• Verify you have entered the proper NetLinx Master IP and connection

methods into the Master Connection section of the System Settings
page.

• Refer to the System Settings Page section on page 107 for more

information.

My Modero panel can’t obtain a
DHCP Address

In requesting a DHCP Address, the DHCP Server can take up to a few
minutes to provide the address.

• Verify there is an active Ethernet connection attached to the rear of

the Modero before beginning these procedures.

• Select Diagnostics > Network Address, from the Main menu and

verify the System number.

• If the IP Address field is still empty, give the Modero a few minutes to

negotiate a DHCP Address and try again.

My NXT-BP battery pack is
blinking when I check the battery
life indicator.

• A blinking battery life LED indicates that there is less than 10% power

charge remaining on the battery.

• It is recommended that you fully charge the battery either in the

NXA-BASE/B battery base or in the NXT-CHG battery charger.

• Refer to the NXA-BASE/B Battery Base Kit (FG2255K) section on

page 22 for more information.

I was using the power from PSN,
and when I connected my
NXA-BASE/B battery base to the
active panel, my screen went
blank.

• Modero battery bases can not be "hot-swapped" or replaced without

powering down the Modero and removing the PSN connector.

If you are currently using a direct power connection to the panel and
then wish to connect an NXA-BASE/B.

First, power-down the panel and detach the rear power connection.
Then, remove any batteries from within the NXA-BASE/B and
connect the battery base to the underside of the panel.

After connecting the base to the un-powered panel, then run power
to the panel by either reconnecting the power cable to the rear of the
panel or inserting the NXT-BP batteries into the NXA-BASE/B.

• Refer to the NXA-BASE/B Battery Base Kit (FG2255K) section on

page 22 and Installing the NXA-BASE/B to an NXT Modero
Panel
section on page 23
for more information.

My WEP doesn’t seem to be
working.

• WEP will not work unless the same default key is set on both the

panel and the AP.

• For example: if you had your access point set to default key 4 which

was 01:02:03:04:05 and you set the Modero to key 1 which was also
01:02:03:04:05 it will not work. You have to set key 4 on the Modero
to 01:02:03:04:0.