beautypg.com

Giv ^glh ^gll ^grd ^gru – AMX Modero NXT-1200V User Manual

Page 142

background image

Programming

130

NXD/T-1200V 12" Modero® Video Wall/Flush Mount Touch Panel

"^" Button Commands (Cont.)

^GIV

Invert the
joystick axis to
move the origin to
another corner.

Parameters 1,2, and 3 will cause a bargraph or slider to be inverted regardless of
orientation. Their effect will be as described for joysticks.

Syntax:

"'^GIV-,'"

Variable:

variable text address range = 1 - 4000.

joystick axis to invert = 0 - 3.

For a bargraph 1 = Invert , 0 = Non Invert

Example:

SEND_COMMAND Panel,"'^GIV-500,3'"

Inverts the joystick axis origin to the bottom right corner.

^GLH

Change the
bargraph upper
limit.

Syntax:

"'^GLH-,'"

Variable:

variable text address range = 1 - 4000.

bargraph limit range = 1 - 65535 (bargraph upper limit range).

Example:

SEND_COMMAND Panel,"'^GLH-500,1000'"

Changes the bargraph upper limit to 1000.

^GLL

Change the
bargraph lower
limit.

Syntax:

"'^GLL-,'"

Variable:

variable text address range = 1 - 4000.

bargraph limit range = 1 - 65535 (bargraph lower limit range).

Example:

SEND_COMMAND Panel,"'^GLL-500,150'"

Changes the bargraph lower limit to 150.

^GRD

Change the
bargraph
ramp-down time
in 1/10th of a
second.

Syntax:

"'^GRD-,'"

Variable:

variable text address range = 1 - 4000.

bargraph ramp down time = In 1/10th of a second intervals.

Example:

SEND_COMMAND Panel,"'^GRD-500,200'"

Changes the bargraph ramp down time to 20 seconds.

^GRU

Change the
bargraph
ramp-up time in
1/10th of a
second.

Syntax:

"'^GRU-,'"

Variable:

variable text address range = 1 - 4000.

bargraph ramp up time = In 1/10th of a second intervals.

Example:

SEND_COMMAND Panel,"'^GRU-500,100'"

Changes the bargraph ramp up time to 10 seconds.

0

2

3

1

1 = Invert horizontal axis

2 = Invert vertical axis
3 = Invert both axis locations

0 = Normal