<9. Parameter Lists>

9-6

IM 01C25T02-01E

Relative

Index Index

Parameter Name

Factory Default Write

Mode

Explanation

18

2018

CAL_MIN_SPAN

Minimum span of

capsule

The minimum calibration span value allowed.

19

2019

CAL_UNIT

kPa

The engineering unit for the calibrated values.

20

2020

SENSOR_TYPE

Silicon resonant

The type of sensor.

21

2021

SENSOR_ RANGE

Range of capsule —

The High and Low range limit values, engineering units code

and the number of digits to the right of the decimal point for the

sensor.

22

2022

SENSOR_SN

Serial No.

Serial number.

23

2023

SENSOR_CAL_

METHOD

103: factory

trim standard

calibration

O/S

The method of the last sensor calibration.

100=volumetric

101=static weight

102=dynamic weight

103=factory trim standard calibration

104=user trim standard calibration

105=factory trim special calibration

106=user trim special calibration

255=Other

24

2024

SENSOR_CAL_LOC —

O/S

Set/indicate the location of the last sensor calibration.

25

2025

SENSOR_CAL_DATE —

O/S

Set/indicate the date of the last sensor calibration.

26

2026

SENSOR_CAL_WHO —

O/S

Set/indicate the name of the person responsible for the last

sensor calibration.

27

2027

SENSOR_

ISOLATOR_MTL

Unkown

Defines the construction material of the isolating diaphragms.

28

2028

SENSOR_FILL_

FLUID

Unkown

Defines the type of fluid used in the sensor.

29

2029

SECONDARY_VALUE

Static pressure (high pressure side) value and status

30

2030

SECONDARY_

VALUE_UNIT

1133 (KPa)

The engineering unit of static pressure (high pressure side).

This unit is linked to XD_SCALE.unit of AI blocks

31

2031

CAL_DEVIATION_HI 0

O/S

Deviation value for span adjustment.

32

2032

CAL_DEVIATION_LO 0

O/S

Deviation value for zero adjustment.

33

2033

EXTERNAL_ZERO_

TRIM

0

O/S

Permission of external zero-adjustment

34

2034

PRIMARY_VALUE_

FTIME

2

O/S

Damping time constant for primary value

35

2035

TERTIARY_VALUE

Value and status of static pressure at low side

36

2036

SP_VALUE_TYPE

109 (absolute

pressure)

O/S

Select the type of measurement for static pressure, absolute

or gauge

37

2037

SP_VALUE_RANGE Range of capsule —

High and low range limit values, engineering units, and decimal

point place for static pressure.

38

2038

CAL_SP_ POINT_HI 16

O/S

The highest calibrated value for static pressure

39

2039

CAL_SP_ POINT_LO 0

O/S

The Lowest calibrated value for static pressure

40

2040

CAL_SP_MIN_ SPAN 1.0

The minimum calibration span allowed for static pressure

41

2041

CAL_SP_UNIT

1133 (KPa)

The calibrated engineering unit for static pressure. This unit is

linked to XD_SCALE.unit of AI blocks

42

2042

CAL_SP_

DEVIATION_HI

0

O/S

Deviation value for span adjustment of static pressure

43

2043

CAL_SP_

DEVIATION_LO

0

O/S

Deviation value for zero adjustment of static pressure

44

2044

SP_VALUE_FTIME

2

O/S

Damping time constant for static pressure

45

2045

ATM_PRESS

101.325

O/S

Atmosphere pressure value used to obtain gauge pressure

value from absolute pressure.

46

2046

CLEAR_CAL

0

O/S

Reset zero and span adjustment to factory calibrated values for

pressure, static pressure, and or all.

47

2047

CAP_TEMP_VAL

Measured capsule temperature value and status.

48

2048

CAP_TEMP_RANGE -50.0 to 130.0°C —

High and low range limit values, engineering units, decimal

point place for capsule temperature.

49

2049

AMP_TEMP_VAL

Measured Amplifier temperature value and status.

50

2050

AMP_TEMP_ RANGE -50.0 to 95.0°C

High and low range limit values, engineering units, decimal

point place for Amplifier temperature.

51

2051

MODEL

Model code

The model code.

52

2052

SPECIAL_ ORDER_

ID

Special order

number

Identification number of special order.

53

2053

MANUFAC_DATE

0

O/S

Date of production