3 bus power on, 1 integral indicator display when powering on, Bus power on -3 4.3.1 – Yokogawa EJX930A User Manual
Page 28: Integral indicator display when powering on -3
<4. Getting Started>
4-3
IM 01C25T02-01E
4.3 Bus Power ON
4.3.1 Integral Indicator Display When
Powering On
Turn on the power of the host and the bus.
For models with the integral indicator code “D”, the
display shows all segments in the LCD and then
changes to the displays shown below sequentially.
All segments display
Model name (3s)
Communication Protocol (3s)
Device Revision (3s)
F0200.ai
NOTE
LCD display can be set to all segments display
only by changing the following parameter.
LCD Tranceducer Block POWER_ON_INFO
1:ON(Default)
Show all segments display, Model name,
Communication Protocol and device revision
when powering on.
0:OFF
Show all segments display when powering on.
4.3.2 Confirming that Transmitter is
Operating Properly
Turn on the power of the host and the bus. If the
indicator is not lit, check the polarity of the power
supply.
The device information, including PD tag, Node
address, and Device ID, is described on the sheet
attached to the transmitter. The device information
is given in duplicate on this sheet.
DEVICE INFORMATION
Device ID
:
594543000CXXXXXXXX
PD Tag
:
PT2001
Device Revision
:
5
Node Address
:
0xf5
Serial No.
:
XXXXXXXXXXXXXXXXX
Physical Location :
Note:
Our Device Description Files and Capabilities Files available at
http://www.yokogawa.com/fld/ (English) or
http://www.yokogawa.co.jp/fld/ (Japanese)
DEVICE INFORMATION
Device ID
:
594543000CXXXXXXXX
PD Tag
:
PT2001
Device Revision
:
5
Node Address
:
0xf5
Serial No.
:
XXXXXXXXXXXXXXXXX
Physical Location :
Note:
Our Device Description Files and Capabilities Files available at
http://www.yokogawa.com/fld/ (English) or
http://www.yokogawa.co.jp/fld/ (Japanese)
F0404.ai
Figure 4.4
Device Information Sheet Attached to
Transmitter
If no transmitter is detected, check the available
address range and the polarity of the power supply.
If the node address and PD tag are not specified
when ordering, default value is factory set. If two
or more transmitters are connected at a time with
default value, only one transmitter will be detected
from the host as transmitters have the same initial
address. Separately connect each transmitter and
set a different address for each.