Revision information – Yokogawa EJX930A User Manual
Page 169
i
IM 01C25T02-01E
Revision Information
Title
: Model EJX Series
Fieldbus Communication Type
Manual No. : IM 01C25T02-01E
Edition
Date
Page
Revised Item
1st
Aug. 2004
—
New publication.
2nd
Feb. 2005
2-2
2.1.2
• Add CSA Certification.
2-2 to 2-4
2.1.3
• Add CENELEC ATEX (KEMA) Intrinsically Safe Type.
2-5
2.1.3
• Add CENELEC ATEX Type of Protection “n”.
10-2
10.3
• Add Optional Codes KS25, KN25, and CF1.
10-2
Factory setting Add Operation Functional Class.
3rd
June 2005
6-4
6.3.5
• Support Amplifier temperature.
6-10
6.5.5
• Enhance AI function block.
APPENDIX 1.
• Add Signal Characterizer block.
APPENDIX 2.
• Add Integrator block.
APPENDIX 3.
• Add Input Selector block.
APPENDIX 4.
• Add Arithmetic block.
APPENDIX 7.
• Add Software download function.
4th
Apr.2006
2-1 to 2-5
2
• Add applicable standard and certificate number for each
approval.
5-8
5.6.3
• Change Table 5.12.
9-5
9.2
• Change parameter list for SENSOR Transducer Block.
A-37
A4.2.3
• Correct the function of “INPUT-OPTS”.
5th
July 2006
2-6
2.1.3
• Change of applicalbe standards for CENELEC ATEX type n.
A-61
A7.5
• Correct the device family code in the file name.
6th
Oct. 2006
2-2
2.1.1
• Add FM Intrinsically safe and Nonincendive approval.
4-1
4.1
• Add Figure 4.2 'Wiring Diagram.'
10-2
10.3
• Add FM Intrinsically safe and Nonincendive approval (/FS15).
7th
Nov. 2007
2-1
2.1.1
• Add warning for EJX130A.
2-9
2.1.4
• Add IECEx Certification.
10-2
10.3
• Add IECEx approvals.
A-67
APPENDIX 8.
• Add "EJX130A ADDITIONAL INFORMATION."
8th
Feb. 2008
—
Remove APPENDIX 8. Add "EJX130A ADDITIONAL INFORMATION."
Add APPENDIX 8. ADVANCED DIAGNOSTICS.
2-1 to 2-10
Revise certificate No. and applicable standards for explosion-proof/flameproof
approvals.
8-6
8.1
• Add alarms for ILBD.
10-1
10.2
• Add /DG1.
10-2
10.3
• Remove /KF2 and Add /KF21.
9th
Aug. 2009
2-5
2.1.2
• Add b. CSA Intrinsically safe and Nonincendive type.
6-5
6.4
• 6.4.3 Delete “F” display.
6-11
6.5.6
• Correct explanation of L_TYPE. Add explanation for LOW_CUT.
9-10
9.4
• Correct explanation for LOW_CUT.
10-2
10.3
• Add process sealing statement for CSA approval. Add /CS15.
A-23
A3.2.1
• Add information of valid input
A-71
Table A8.2 • Add model EJX115A.
A-90
A8.3.1
• Correct calculation formula.
10th
Apr. 2010
2-1 to 2-12
2.1
• Add limitation of ambient temperature for /HE.
10-2 to 10-3
10.3
• Add limitation of ambient temperature for /HE.
11th
Mar. 2012
2-1
2.1
• Add note for blind plugs.
4-3
4.3
• Change URL in Figure 4.4.
A4-4
A4.3.1
• Change formula in 10).