App.measure.px.operator (paramengine = "tie"), Hysteresis, Range – Teledyne LeCroy WaveRunner Automation Command User Manual
Page 449: Annotate

Automation Command and Query Reference Manual - Processor Reference
Hysteresis
Double
From 0 to 10 step 0.1
Range
Hysteresis
Double
TIE
app.Measure.Px.Operator (ParamEngine = "TIE")
TIE is "Time Interval Error", or the error in expected arrival time of trnasotions in either a data stream or a clock signal.
It is the heart of most jitter measurments (where only one signal is under analysis). The Skew processor is closely
related to this function in cases where measurements are using a separate reference clock.
WARNING: The TIE processor is appropriate for analysis of "real-time" acquired waveforms for jitter and timing
variations. It will give incorrect results for equivalent-time type waveforms.
Annotate
Integer
From 1 to 10 step 1
Range
Annotate
Integer
BaseFrequency
Double
DataIsNRZ
Bool
FindBaseFrequency
Action
FindLevel
Action
FrequencyMultiplier
Double
Hysteresis
Double
IncludeVirtualEdges
Bool
IntervalsEdgeEdge
Integer
IntervalType
Enum
LevelType
Enum
MaxComboIntervals
Integer
PercentLevel
Double
PermitGTHalfUI
Bool
PLL1TransportDelay
Double
PLLCompensateForMissingEdges
Bool
PLLFrequency
Double
PLLType
Enum
SignalType
Enum
Slope
Enum
Summary
String
UseAllEdges
Bool
UseBaseFrequency
Enum
UseMultiEdgeCombos
Bool
UsePLL
Bool
VirtEdgeType
Enum
2-118