beautypg.com

IAI America ISWA User Manual

Page 54

background image

46

1

1. Procedure for Motor Replacement

11.1.1.2

Removing the Motor Cover

Remove the six bolts that secure the motor cover.

11.1.1.3

Removing Wire/Cable Lines for the Motor Unit

(1) Remove the ground line, which is bolted to the motor bracket.

(2) Disconnect the encoder signal line connector and the motor power line connector.

If a brake is provided, the brake lead connector should also be disconnected.

Type

Motor

output

(W)

Location

Bolt used

Nominal

Diameter

Length Quantity

S

60

Top side

M4

18

2

Bottom side

18

4

M

100

Top side

M5

20

2

Bottom side

20

4

200

Top side

M5

20

2

Bottom side

20

4

L

200

Top side

M6

20

2

Bottom side

20

4

400

Top side

M6

20

2

Bottom side

20

4

* There is a sealing washer applied with the top two

screws.

Top side

Bottom side

This manual is related to the following products: