beautypg.com

6 air purge for splash-proof type – IAI America ISWA User Manual

Page 36

background image

28

5. Installation

5.6

Air Purge for Splash-Proof Type

By supplying dry, compressed air into the actuator, it performs dust proof and splash proof (water and

dust) of IP65

*1

.

Instruction below shows how to perform air purge.

Air purge is performed with using the quick joint (O.D.

I6) on the rear cover. Supply air from the upper

joint.

The lower quick joint is used as a drain joint (a hole to withdraw water) in the case that water gets inside

the actuator. Connect a

I6 air tube and take it to a place where no water or dust gets in to withdraw

water.

1. Actuator Air Pressure … 0.1MPa to 0.2MPa(approx. 1kgf/cm

2

to 2kgf/cm

2

)

2. Air Flow … Approx.20 to 40Nl/min

3. Applied Air … Do not supply air directly from a compressor. Make sure to supply dry compressed air

via an air drier.

Air to supply should not contain compressor oil and should be clean dry air that has

SDVVHGWKHDLU¿OWHUZLWKWKH¿OWUDWLRQRIȝPPD[DQGWKDWLVGULHGLQDWPRVSKHULF

dew point of -20°C max.

*1

Primary Characteristic No.1

Protection Level to Outer Solid Body

6

No dust gets inside

Primary Characteristic No.2

Protection Level to Water Penetration

5

1RKDUPIXOLQÀXHQFHLVRFFXUUHGE\ZDWHU

splashed from any angle.
,QWKHVWDQGDUGLWLVVSHFL¿HGWKHSUHVVXUHRI
splash water is 30KPa (30KN/m

2

, 0.3kgf/cm

2

),

splash speed is 12.2L/min and duration is for
3min.

Air Supply Joint

Drain Joint