4 datum surface and mounting surface – IAI America ISWA User Manual
Page 34
26
5. Installation
5.4
Datum Surface and Mounting Surface
x 7KHPRXQWLQJIUDPHVKRXOGKDYHVXI¿FLHQWULJLGLW\WRDYRLGJHQHUDWLRQRIYLEUDWLRQ
x The surface where the actuator will be mounted should be machined or be equally level, and the
ÀDWQHVVEHWZHHQWKHDFWXDWRUDQGWKHIUDPHVKRXOGEHZLWKLQPP
x Provide enough space around the actuator so that maintenance work can be carried out.
x The side and bottom of the actuator base provide reference planes for slider travel.
x When traveling precision is required, use these surfaces as the reference for mounting.
:KHQLQVWDOOLQJWKHXQLWRQWKHSODWIRUPXVLQJWKHGDWXPVXUIDFHIROORZWKH¿JXUHVKRZQEHORZIRUWKH
SODWIRUPSUR¿OH
As shown in the picture above, the base side surfaces work as the datum for the slider’s run. If
accuracy is required, use these surfaces as a datum for the installation.
Datum Surface
Datum Surface
Under R0.3
A dimensions (mm)
3 to 5