Installation, 1 attachment, 2 installing the main body – IAI America ISWA User Manual
Page 30
22
5. Installation
5.
Installation
Stated below tells how to install the actuator to a mechanical equipment.
5.1
Attachment
This actuator is recommended for a standard horizontal mount for the posture of installation to fully
SHUIRUPLWVGXVWSURRIDQGVSODVKSURRIVSHFL¿FDWLRQV2WKHUSRVWXUHVRILQVWDOODWLRQKRUL]RQWDOZDOO
mount, up-side-down or vertical mount) may allow water to get inside.
5.2
Installing the Main Body
There are tapped holes on the back of the actuator base for installation. Please utilize these holes to
install the unit.
Shown below is the mounting dimension explained in a section.
Machine Type
Tap diameter
Tap Effective length
A
Small Size
M6
17mm
70mm
Medium Size
M8
20mm
90mm
Large Size
M8
20mm
120mm
Bolt to
be used
Tightening Torque
In the case that steel is used for
the bolt seating surface:
In the case that aluminum is used for
the bolt seating surface:
M6
12.3N•m(1.26kg•m)
5.4N•m(0.55kg•m)
M8
30.0N•m(3.06kg•m)
11.5N•m(1.17kg•m)
Surface for screw seat
Screw
Screw-seated surface
Screw-seated surface