beautypg.com

Appendix ii: ecolab instrument sanitation, A. safety precautions, B. sanitation procedures – Fairbanks NexWeigh User Manual

Page 76

background image

04/14

76

51216 -- Rev. 6

Appendix II: ECOLAB Instrument Sanitation

A. SAFETY PRECAUTIONS

When using potentially harmful cleaners and chemicals, always
wear goggles or a face shield, boots, gloves, and a chemical
apron.

Use Lock-out/Tag-Out policies, as required by plant
procedures.

Do not use steam or high-pressure water at any time in the
cleaning procedures.

Always walk “flat-footed”, using caution on the wet floors.

Chemical step
temperature

Product

Amount

Concentration

Time

Temp.

Manual Brush

HC-10, or similar
product

3 to 5 oz. per
gallon water

N/A

Hand Brush

110°

Sanitize

Quorum Clear,
or similar product

1 oz. to 4
gallons water

200 PPM

30 seconds
mim. contact

Ambient

B. SANITATION PROCEDURES

Following these steps to fully clean and sanitize the scale and work area.

3. Sweep and pick up all trash, placing it in proper containers for disposal.

4. Cover all electrical outlets and other non-waterproof items with plastic tarps.

5. Cover the Scale Enclosure Weldment with waterproof

material.

6. Protect all exposed product and/or packaging materials with

plastic tarps and package wraps.

─ Remove these from the area to be

cleaned, whenever

possible and appropriate.

7. Hand-wipe any visible soil on the Scale Enclosure

Weldment.

─ Use a paper towel containing an industrial strength

detergent, like 200 ppm Quorum Clear.