Appendix II: ECOLAB Instrument Sanitation
A. SAFETY PRECAUTIONS
When using potentially harmful cleaners and chemicals, always
wear goggles or a face shield, boots, gloves, and a chemical
apron.
Use Lock-out/Tag-Out policies, as required by plant
procedures.
Do not use steam or high-pressure water at any time in the
cleaning procedures.
Always walk “flat-footed”, using caution on the wet floors.
Chemical step
temperature
Product
Amount
Concentration
Time
Temp.
Manual Brush
HC-10, or similar
product
3 to 5 oz. per
gallon water
N/A
Hand Brush
110°
Sanitize
Quorum Clear,
or similar product
1 oz. to 4
gallons water
200 PPM
30 seconds
mim. contact
Ambient
B. SANITATION PROCEDURES
Following these steps to fully clean and sanitize the scale and work area.
3. Sweep and pick up all trash, placing it in proper containers for disposal.
4. Cover all electrical outlets and other non-waterproof items with plastic tarps.
5. Cover the Scale Enclosure Weldment with waterproof
material.
6. Protect all exposed product and/or packaging materials with
plastic tarps and package wraps.
─ Remove these from the area to be
cleaned, whenever
possible and appropriate.
7. Hand-wipe any visible soil on the Scale Enclosure
Weldment.
─ Use a paper towel containing an industrial strength