Section 5: Serial I/O

04/14

52

51216 -- Rev. 6

5.4.8. NexWeigh Serial Commands and Definitions,

Continued

z)

Set Flush Filter Band

Definition: Used to set scale’s flush filter band in divisions. Only valid settings allowed.

Command: ‘SFF’ ‘divisions’

Options:

1, 2, 5, 10, 20, 50, 100, 5000,

Sample Command: "SFF 5000 \r"

aa)

Set Display Intensity

Definition: Used to set scales display intensity parameter. Only valid settings allowed.

Command: ‘SDI’ ‘level’

Options:

1-7

Sample Command: "SDI 4\r"

bb)

Set Zero Limit

Definition: Used to set the scales zero limit parameter. 100% for USA or 2% for
Canada. Only valid settings allowed.

Command: ‘SZL’ ‘range’

Options:

100, 2

Sample Command: "SZL 100\r"

cc)

Set OverLoad Limit

Definition: Used to set the scales Over capacity limit parameter. Range is in %. Only
valid settings allowed.

Command: ‘SOL’ ‘range’

Options:

102.5, 105.0, 110.0, 150.0 etc.

Sample Command: "SOL 102.5\r"

dd)

Set UnderLoad Limit

Definition: Used to set the scales Under capacity limit parameter. Range is in %.
Only valid settings allowed.

Command: ‘SUL’ ‘range’

Options:

25, 50, 100, etc.

Sample Command: "SUL 25\r"

ee)

Set Custom Factor

Definition: Used to set the custom units conversion factor. Value is a number representing
conversion from primary unit to custom unit, i.e. 8.33 lbs per gallon of water.

Command: ‘SCF’ ‘value’

Options:

decimal value

Sample Command: "SCF 8.33 \r"