5.4.8. NexWeigh Serial Commands and Definitions,

Continued

qq)

Set Output Time Enable

Definition: Used to set the Output Scale Time enable parameter for the scales serial
output stream.

Command: ‘SOT’ ‘mode’

Options:

E,D

Sample Command: "SOT E\r"

rr)

Set Output Date Enable

Definition: Used to set the Output Scale Date enable parameter for the scales serial
output stream.

Command: ‘SOD’ ‘mode’

Options:

E,D

Sample Command: "SOD E\r"

ss)

Set AutoPrint AutoAccumulate Out Enable

Definition: Used to set the Auto Print Auto Accumulate Out enable parameter for the
scale.

Command: ‘SAA’ ‘mode’

Options:

E,D

Sample Command: "SAA E\r"

tt)

Set Output Format

Definition: Used to set the Output Scale Format parameter for the scales serial
output stream. GTN or NET only

Command: ‘SOF’ ‘mode’

Options:

GTN, NET

Sample Command: "SOF GTN\r"

Sample Command: "SOF NET\r"

uu)

Set AutoPrint Threshold

Definition: Used to set the Auto print threshold limit in divisions.

Command: ‘SAP’ ‘divisions’

Options:

Integer value

Sample Command: "SAP 10\r"