Weight accumulation, continued, Peak hold weighing – Fairbanks NexWeigh User Manual
Page 69
Section 6: Operations
04/14
69
51216 -- Rev. 6
6.3.5. Weight Accumulation, Continued
J. Accumulation Notes.
1. No units switching is allowed if Accumulation is currently activated, or if an
accumulation has been stored and not cleared. The message NoUntS will be
displayed if
UNITS
is pressed.
2. On power up or return from Program mode or Checkweigh Setup mode, if an
accumulation has been stored in units other than Primary Units (PU in config
menu), the accumulation units will be automatically selected.
3. If the accumulation units are no longer enabled on power up or return from
Program mode or Checkweigh Setup mode, the accumulated values will be
cleared and Primary Units will be selected.
6.3.6. Peak Hold Weighing
A. Enabling PEAK HOLD
1. Press and hold
OVER/UNDER/NEXT
until display indicates ChEc.
2. Press
OVER/UNDER/NEXT
to display HoLd.
3. Press
PROGRAM/ENTER
to display HoLd X, where X is either Y or n.
4. Press
OVER/UNDER/NEXT
to display HoLd Y if necessary.
NOTE:
The Peak Hold function must not be used with Checkweighing.
5. Press
PROGRAM/ENTER
to display CSAvEd, and returns to weigh mode.
Instrument is now in Peak Hold mode.
B. Operating Peak Hold
1. Press the
1 (one)
button to activate Peak Hold mode. The first three
instruments for UNDER, ACCEPT and OVER will flash indicating Peak Hold is
active. Also the instruments on the
1
,
2
, and
3
buttons will be on.