6.1. BASIC SCALE OPERATIONS

Upon power up the Instrument performs a warm-up cycle.

The Instrument initiates a test, displaying numbers

1

to

8

, and lights up all LED’s.

The Program number and Revision Information displays.

The Instrument then displays the current weight on the scale

6.2. KEYPAD FUNCTIONS, WEIGH MODE

KEY

ACTION

Recipe 1-4

Enables or disables programmed recipe in Checkweigh mode.

In peak weigh mode, 1 enables peak, 2 disables, and 3 resets peak.

TARE

Automatically tares off the displayed weight.

If held for 3 seconds, enables or disables accumulate function.

ZERO

Resets gross weight to center of zero.

PROGRAM/ENTER

Captures weight and adds to accumulation if enabled.

OVER/UNDER/NEXT

Displays accumulated weight and number of weighments if enabled.

If held for 3 seconds, enters Checkweigh or peak weight setup.

UNITS

Switches between selected weighting units.

If held for 3 seconds, enters 4-20mA parameters if enabled.

B/G – NET

Toggles between GROSS and NET WEIGHTS.

If held for 10 seconds, displays audit trail functions.

PRINT