Basic scale operations, Keypad functions, weigh mode – Fairbanks NexWeigh User Manual
Page 63
04/14
63
51216 -- Rev. 6
Section 6: Operations
6.1. BASIC SCALE OPERATIONS
Upon power up the Instrument performs a warm-up cycle.
•
The Instrument initiates a test, displaying numbers
1
to
8
, and lights up all LED’s.
•
The Program number and Revision Information displays.
•
The Instrument then displays the current weight on the scale
6.2. KEYPAD FUNCTIONS, WEIGH MODE
KEY
ACTION
Recipe 1-4
Enables or disables programmed recipe in Checkweigh mode.
•
In peak weigh mode, 1 enables peak, 2 disables, and 3 resets peak.
TARE
Automatically tares off the displayed weight.
•
If held for 3 seconds, enables or disables accumulate function.
ZERO
Resets gross weight to center of zero.
PROGRAM/ENTER
Captures weight and adds to accumulation if enabled.
OVER/UNDER/NEXT
Displays accumulated weight and number of weighments if enabled.
•
If held for 3 seconds, enters Checkweigh or peak weight setup.
UNITS
Switches between selected weighting units.
•
If held for 3 seconds, enters 4-20mA parameters if enabled.
B/G – NET
Toggles between GROSS and NET WEIGHTS.
•
If held for 10 seconds, displays audit trail functions.
Transmits transaction data out COM port 1 if button is selected.