6.3.5. Weight Accumulation
A. Starting Accumulation mode.
1. If instrument is not in accumulate mode, press and hold
TARE
to enable
accumulate mode. Instrument will display ACC on briefly.
Note: If Accumulate function is not enabled in APP menu, display will flash
and return to displaying current weight without showing ACC-on.
2. Press
ZERO
, if required, to set scale to “0”.
3. If accumulation is using a container, apply container and press
TARE
to
place scale in net mode.
4. Apply product to be accumulated to platform.
There are four different possibilities of configuring the accumulation function. Each
one will be addressed separately as follows:
B. Port 1 set to Auto and Aout set to yes.
1. After weight is applied, and if the weight is greater than the accumulate
threshold, the instrument will flash all the green ACCEPT LEDs for one second
showing that the weight has been stored as an accumulation and then transmit
the following data string:
“Weight nn = wwwwww uu GR/NT”
nn is the number of the current accumulated weight in numerical order.
wwwwww is the last accumulated weight.
uu is the unit of weight accumulated.
GR or NT represent whether accumulated weight is gross or net respectively.
2. Weight on the scale must now be removed to less than .5 grads before the
next accumulation can occur.
3. If a reprint of the last accumulated weight is required, press
and port 1
will retransmit the string indicated above.
4. Repeat steps 1-3 to continue accumulations (up to 99).