beautypg.com

Configuration menu, continued o.r, Filter – Fairbanks NexWeigh User Manual

Page 28

background image

Section 4: Programming Configuration

04/14

28

51216 -- Rev. 6

4.5.2. Configuration Menu, Continued

O.r:

Programming the zero range: (the percentage of scale capacity that may be

removed by pressing the Zero Key). The display will indicate

O.r X

where

X

is the

current setting. Press

OVER/UNDER/NEXT

,

UNITS

or

TARE

to change the

selection. Press

PROGRAM/ENTER

to enter the selection. Available selections

are:

100

100 percent zero range

2

2 percent zero range

d:

Programming the division size: The display will indicate

d

followed by the

current division size setting. Press

OVER/UNDER/NEXT

or

UNITS

to scroll up,

or

TARE

to scroll down through the available choices. Press

PROGRAM/ENTER

to enter the selection. Available selections are:

50

20

10

5

2

1

0.5

0.2

0.1

0.05

0.02

0.01

0.005

0.002

0.001

0.0005 0.0002 0.0001


FiLtEr:

Programming the filter setting: (intended to minimize the effects of

motion, vibration, and wind currents) The display will indicate

FiLtEr

followed by the

current filter setting. Press

OVER/UNDER/NEXT

or

UNITS

to scroll up, or

TARE

to scroll down through the available choices. Press

PROGRAM/ENTER

to enter the selection. Available selections are:

1

3

5

11

15

20

30

50

FLF:

Flush filter factor: Allows instrument to switch to fast filter rate if weight

change exceeds the number of divisions in setting. The display will indicate

FLF

followed by the current setting. Press

OVER/UNDER/NEXT

or

UNITS

to scroll

up, or

TARE

to scroll down through the available choices. Press

PROGRAM/ENTER

to enter the selection. Available selections are:

oFF

1

2

5

10

20

50

100