Configuration menu, continued o.r, Filter – Fairbanks NexWeigh User Manual
Page 28
Section 4: Programming Configuration
04/14
28
51216 -- Rev. 6
4.5.2. Configuration Menu, Continued
O.r:
Programming the zero range: (the percentage of scale capacity that may be
removed by pressing the Zero Key). The display will indicate
O.r X
where
X
is the
current setting. Press
OVER/UNDER/NEXT
,
UNITS
or
TARE
to change the
selection. Press
PROGRAM/ENTER
to enter the selection. Available selections
are:
100
100 percent zero range
2
2 percent zero range
d:
Programming the division size: The display will indicate
d
followed by the
current division size setting. Press
OVER/UNDER/NEXT
or
UNITS
to scroll up,
or
TARE
to scroll down through the available choices. Press
PROGRAM/ENTER
to enter the selection. Available selections are:
50
20
10
5
2
1
0.5
0.2
0.1
0.05
0.02
0.01
0.005
0.002
0.001
0.0005 0.0002 0.0001
FiLtEr:
Programming the filter setting: (intended to minimize the effects of
motion, vibration, and wind currents) The display will indicate
FiLtEr
followed by the
current filter setting. Press
OVER/UNDER/NEXT
or
UNITS
to scroll up, or
TARE
to scroll down through the available choices. Press
PROGRAM/ENTER
to enter the selection. Available selections are:
1
3
5
11
15
20
30
50
FLF:
Flush filter factor: Allows instrument to switch to fast filter rate if weight
change exceeds the number of divisions in setting. The display will indicate
FLF
followed by the current setting. Press
OVER/UNDER/NEXT
or
UNITS
to scroll
up, or
TARE
to scroll down through the available choices. Press
PROGRAM/ENTER
to enter the selection. Available selections are:
oFF
1
2
5
10
20
50
100