beautypg.com

Weight accumulation, continued, Check weighing – Fairbanks NexWeigh User Manual

Page 70

background image

Section 6: Operations

04/14

70

51216 -- Rev. 6

6.3.5. Weight Accumulation, Continued

2. The display will now freeze on the largest weight applied to the platform. It will

remain there even after weight is removed.

3. To deactivate the Peak Hold function while retaining the current peak weight,

press the

2

button. Instrument will now return to normal weigh mode. Any

weight applied now will not affect the stored peak weight.

4. To deactivate Peak Hold and clear the current peak weight, press the

3

button. Instrument now returns to normal weigh mode.

5. To reactivate Peak Hold after pressing either

2

or

3

,

press

1

.

6.3.7. Check Weighing

The NexWeigh instrument uses a three color bargraph to indicate an item’s weight
within three bands, Under, Accept, and Over. It is capable of storing four “recipes” or
different Checkweigh configurations for four different products. Default selections are
underlined.

Follow these steps to configure the Check Weigh Mode.

1. Press and hold

OVER/UNDER/NEXT

until display indicates ChEc.

2. Press

PROGRAM/ENTER

to display rEC 1. This indicates that the

instrument is ready to accept configuration of recipe 1.

3. If another recipe is to be configured, press

OVER/UNDER/NEXT

to scroll

through to rEC 2, rEC 3, or rEC 4.

4. With the desired recipe displayed, press

PROGRAM/ENTER

to display

EnA Y, or EnA n.

NOTE:

If

EnA n

is selected in this step, the instrument will advance to the next

enabled format, or return to the

ChEc

prompt if none are enabled.

5. To toggle between choices press

OVER/UNDER/NEXT

. Selecting Y will

enable the current recipe, and selecting n will disable it.

6. Press

PROGRAM/ENTER

to advance to nEt n, or nEt Y.