6.3.5. Weight Accumulation, Continued
2. The display will now freeze on the largest weight applied to the platform. It will
remain there even after weight is removed.
3. To deactivate the Peak Hold function while retaining the current peak weight,
press the
2
button. Instrument will now return to normal weigh mode. Any
weight applied now will not affect the stored peak weight.
4. To deactivate Peak Hold and clear the current peak weight, press the
3
button. Instrument now returns to normal weigh mode.
5. To reactivate Peak Hold after pressing either
2
or
3
,
press
1
.
6.3.7. Check Weighing
The NexWeigh instrument uses a three color bargraph to indicate an item’s weight
within three bands, Under, Accept, and Over. It is capable of storing four “recipes” or
different Checkweigh configurations for four different products. Default selections are
underlined.
Follow these steps to configure the Check Weigh Mode.
1. Press and hold
OVER/UNDER/NEXT
until display indicates ChEc.
2. Press
PROGRAM/ENTER
to display rEC 1. This indicates that the
instrument is ready to accept configuration of recipe 1.
3. If another recipe is to be configured, press
OVER/UNDER/NEXT
to scroll
through to rEC 2, rEC 3, or rEC 4.
4. With the desired recipe displayed, press
PROGRAM/ENTER
to display
EnA Y, or EnA n.
NOTE:
If
EnA n
is selected in this step, the instrument will advance to the next
enabled format, or return to the
ChEc
prompt if none are enabled.
5. To toggle between choices press
OVER/UNDER/NEXT
. Selecting Y will
enable the current recipe, and selecting n will disable it.
6. Press
PROGRAM/ENTER