Section 6: Operations
04/14
71
51216 -- Rev. 6
6.3.7. Check Weighing, Continued
7. Press
OVER/UNDER/NEXT
to toggle between nEt n, (Checkweigh in
gross mode) or nEt Y, (Checkweigh in net mode).
8. Press
PROGRAM/ENTER
to display diS Y, or diS n. This will determine
whether the numeric display is active or not while Checkweighing is active.
9. Press
OVER/UNDER/NEXT
to toggle between diS Y, and diS n.
Note:
If weighing in net mode and numeric display is active, the instrument can
accidentally be placed in the
GROSS mode
and the display then might not match
the Checkweigh indication.
10. With the desired selection displayed, press
PROGRAM/ENTER
to display
UnitS With UnitS displayed, one of the units legends will be lit. This is the
weigh units the Checkweigh limits will be defined by in the following steps.
11. Press
OVER/UNDER/NEXT
to scroll through the choices, including custom
units.
12. With the desired units legend lit, press
PROGRAM/ENTER
to display
hAnd Y, or hAnd n. This determines the method for defining the acceptance
band. Using hAnd Y provides the user the ability to enter all ranges manually,
whereby hAnd n provides the user the ability to use a sample weight for the
accept target range.
13. Press
OVER/UNDER/NEXT
to toggle between the two choices.
14. With the desired selection displayed, press
PROGRAM/ENTER
.
If hAnd Y is selected, go to step 21.
15. If hAnd n is selected, the instrument will display live weight along with
scrolling under, accept, and over instruments. The instrument is waiting for an
acceptance range weight to be applied. Apply a sample weight of an
acceptable value and press
PROGRAM/ENTER
. This weight will be used
to assist defining the start of accept and end of accept values.